4
6 Settings
6.1 The sensor is to switch when the object is detected
1
►
Position the object.
►
Press [OUT on] for 2 s.
> The LED flashes.
2
►
Remove the object.
►
Press [OUT off].
> The LED goes out. The programming is finished.
6.2 The sensor is not to switch when the object is detected
►
Position the object (see figure 1) and press [OUT off] for 2 s.
►
Remove the object (see figure 2) and press [OUT on].
The setting can also be carried out first without object and then with object.
6.3 Setting of the maximum sensitivity
►
Align the sensor so that no light is reflected.
The sensor is to switch when the object is detected.
►
First press [OUT on], then [OUT off].
The sensor is to switch when the object is not detected
First press [OUT off], then [OUT on].
6.4 Programming unsuccessful
> The yellow LED flashes quickly (8 Hz).
• Insufficient difference in measurements.
• Max. programming time (15 min.) exceeded.