6
6 Electrical connection
The unit must be connected by a qualified electrician�
►
The national and international regulations for the installation of electri-
cal equipment must be adhered to�
►
Ensure voltage supply to EN 50178�
►
Disconnect power�
►
Connect the unit as follows:
6.1 PNP
Connector M12 pigtail
Cable
BK: black
BN: brown
BU: blue
Colours to DIN EN 60947-5-2
Connector M8 3-pin
Connector M8 4-pin
2
1
4
3
6.2 NPN
Connector M12 pigtail
Cable
L+
L
1
4
3
BK: black
BN: brown
BU: blue
L
BN
BK
BU
L+
Colours to DIN EN 60947-5-2
Connector M8 3-pin
Connector M8 4-pin
L+
L
1
4
3
2
1
4
3
L+
L
1
4
3