17
3D sensor
UK
8. Indicators
Via the LED indicators 1 - 4 the sensor signals the current operating state.
LED 4
LED 3
LED 1
LED 2
LED 4
(Ethernet)
LED 1
(Power)
LED 2
(Out 1)
LED 3
(Out 2)
Description
On
Sensor is ready for operation, supply voltage applied
Flashes
at 0.5 Hz
No parameters set or parameter setting was not
loaded into the sensor
On
On
Off
Off
Flashes
2x at 0.5
Hz
Sensor is in the parameter setting mode
On
On
Off
Off
On
Switching output 1 switched
Flashes
at 8 Hz
Switching output 1 shorted
On
Switching output 2 switched
Flashes
at 8 Hz
Switching output 2 shorted
On
Ethernet connected
Flashes
Ethernet transmitting data
Off
Ethernet not connected
Flashes
at 8 Hz
Flashes
at 8 Hz
Sensor signals internal error
Flashes
at 2 Hz
Flashes
at 2 Hz
Sensor signals correctable error. The error information
can be read via Ethernet
Running light
⇒
Device booting
Running light
⇐
Sensor carrying out firmware update