7  Maintenance, repair and disposal

If used correctly, no maintenance and repair measures are necessary�

 

The device must only be repaired by the manufacturer�

 

► After use dispose of the device in an environmentally friendly way in 

accordance with the applicable national regulations.

 

Keep the front lens free from soiling�

 

► Use glass cleaner as cleaning agent.

 

> Cleaning agents containing solvents can damage the front glass�

 

Do not open the device�

 

>

Only the manufacturer is allowed to open the device.

8  Approvals/standards

The EU Declaration of Conformity is available at www.ifm.com.

Summary of Contents for O3D3 Series

Page 1: ...Quick reference guide 3D sensor O3D3XX 80284264 00 09 2019 UK...

Page 2: ...marks 3 1 4 Open source information 4 2 Safety instructions 5 2 1 Safety note 6 3 Functions and features 6 4 Items supplied 7 5 Installation 8 5 1 Mounting accessories 9 6 Electrical connection 9 6 1...

Page 3: ...terference Information Supplementary note 1 2 Warnings used ATTENTION Type and source of the hazard Damage to property may result Actions to refrain from Measures to take 1 3 Copyright and trademarks...

Page 4: ...plies to the software either version 3 of the License or at your option any later version The following disclaimer of the software developers applies to the software components that are subject to the...

Page 5: ...the system This documentation must contain all necessary information and safety instructions for the operator the user and if applicable for any service personnel authorised by the manufacturer of th...

Page 6: ...to threshold values The comparative and process values are linked to the digital outputs This allows to implement many applications The measured data and process values can be provided via Ethernet an...

Page 7: ...ce guide Only use accessories from ifm electronic Available accessories www ifm com The optimum function is not ensured when using components from other manufacturers The device is supplied without in...

Page 8: ...the focus adjustment screw is freely accessible with a screw driver Mount the sensor with spring washers with max 3 Nm Use spring washers for the O3D30x devices only Fig 1 installation with clamp left...

Page 9: ...l of the following measures Adjust the operating mode Make sure the device is sufficiently cooled e g with cooling element and heat conductor Use a contact protection ATTENTION The device must be conn...

Page 10: ...ve caps are not fully tightened Firmly tighten the power supply and connection cables Tightening torque 0 6 0 8 Nm Firmly tighten the protective caps to the unused sockets article no E73004 Tightening...

Page 11: ...Shield 2 Power supply M12 connector A coded 8 poles 6 2 1 4 5 7 3 8 1 U 2 trigger input 3 GND 4 switching output 1 digital or analogue 5 switching output 3 ready 6 switching output 2 digital 7 switchi...

Page 12: ...e in an environmentally friendly way in accordance with the applicable national regulations Keep the front lens free from soiling Use glass cleaner as cleaning agent Cleaning agents containing solvent...

Page 13: ...13 UK...

Reviews: