9 Operating modes
9.1 Run mode
The run mode is the normal operating mode.
After power on the unit is in the Run mode. It carries out its monitoring function and generates output
signals according to the set parameters.
The display indicates the current distance, the yellow LEDs signal the switching state of the outputs.
9.2 Display mode
Indication of the parameters and the set parameter values.
u
Briefly press [MODE/ENTER].
w
The unit goes to the display mode. Internally it remains in the operating mode. The set
parameter values can be read:
u
To scroll through the parameters, briefly press[MODE/ENTER].
u
To display the corresponding parameter value, briefly press [SET].
w
After another 15 s the unit returns to the Run mode.
9.3 Object reflectivity
Indication of the object reflectivity.
u
Press [SET] in the Run mode.
w
The unit displays an orientation value for the object reflectivity (e.g. +100 corresponds to a white
object, +020 corresponds to a grey object).
9.4 Programming mode