6
2.3 Interference of electronic and medical devices
Operation of the unit can affect the function of electronic devices that are not
correctly shielded�
► Disconnect the device in the vicinity of medical equipment�
► Contact the manufacturer of the corresponding device in case of any interfer-
ence�
3 Items supplied
1 RFID-coded safety sensor, 1 RFID-coded actuator,
4 washers, 8 cover caps,
1 x original operating instructions, ident number 80256459�
If one of the above-mentioned components is missing or damaged, please contact
one of the ifm branch offices�
4 Functions and features
RFID-coded safety sensors detect the corresponding actuators (ID-tags) without
contact�
Coding levels according to EN ISO 14119:
Sensor type
Performance
Coding level
Coded
Each sensor recognises each actuator of this type�
low
Codable
The sensor can be programmed for a specific actuator�
low
Unique coding The sensor only detects the actuator with the corre-
sponding coding�
high
Safety-related function SF: The safe state (output stage switched off; Logic "0") is
achieved if the distance to the actuator is greater than or equal to the safe switch
off distance s
ar
► Observe the notes on installation (→ 6 Installation)�
The RFID-coded safety sensor has been certified by TÜVSüd�