Approach curves of the sensors at www�ifm�com:
→ General information about mounting and operation
6 Installation
6.1 Actuating directions
The sensor recognises the actuator from three different directions
2
�
► When mounting the device, align the central marks
1
of the sensor and the actuator
in parallel to each other�
1
2
1
Reference marks (central mark)
2
Actuating direction
• The actuator must not touch the sensor during operation�
• Do not adjust the device using mechanical force�
• Only mount on a flat surface to avoid damage or changes of the sensing range�
When using several sensors, a minimum distance of 50 mm in each direc-
tion must be maintained�
► Fasten the sensor and the actuator with two screws each (M4, > 18 mm) (tight-
ening torque 0�8���2 Nm)�
Using less than two screws for each component is not permissible�
According to EN ISO 14119, the actuator must be fixed immovably�
Safety screws with one-way heads, rivets or the like are to be used�
After mounting, insert the supplied cover caps to make it more difficult to access