5 Function
ACT
IN
OUT
PWR
1
LED
2
Operating area
3
Switch-on distance s
n
(= 12 mm)
4
Limit range
5
Safe switch-off distance s
ar
(= 16 mm)
5.1 Limit range and operating range
LED states when aligning the sensor with the actuator
Status
Description
LED
PWR
OUT
IN *
)
ACT
ACT
IN
OUT
PWR
Actuator outside the limit area
4
Nominal voltage connected
> Inputs active
> Outputs deactivated
ACT
IN
OUT
PWR
Actuator within the actuating area
2
> Outputs activated
ACT
IN
OUT
PWR
Actuator leaves actuating area
2
and is in the
limit area
4
> Outputs remain active
ACT
IN
OUT
PWR
The distance of the actuator to the sensor is larger
than or equal to s
ar
5
> Outputs deactivated
*
)
LED [IN] is not on in case of MN700S and MN703S�