UK
Operating instructions FX460
39
SCROLL DISPLAY
Display change
d
CLEAR LOOP TIME
All defined switching conditions enabled
START PRESELECTION
N�A�
ACTIVATE
N�A�
STORE DATA
N�A�
TESTPROGRAM
N�A�
SET RED COLOR
Display is red� The colour can be changed by means of the
event-dependent colour change in the PRESELECTION 1 ��� 4
MENU�
d
SET GREEN COLOR
Display is green� The colour can be changed by means of the
event-dependent colour change in the PRESELECTION 1 ��� 4
MENU�
d
SET YELLOW COLOR
Display is yellow� The colour can be changed by means of the
event-dependent colour change in the PRESELECTION 1 ��� 4
MENU�
d
INCREMENT BATCH
Increment the batch counter (see COUNTER mode)
d
DECREMENT BATCH
Decrement the batch counter (see COUNTER mode)
d
SET BATCH / TOTAL
Set / reset of the batch counter / total counter (see COUNTER
mode)
d, s
INC� BRIGHTNESS
Increase display brightness
d, s
DEC� BRIGHTNESS
Decrease display brightness
d, s
SET TOTAL TIME
Set / reset of the total timer (see COUNTER mode)
d, s
SET COUNTER A
Set / reset of the value of channel A to the value of SET VALUE
(only in COUNTER mode)
d, s
SET COUNTER B
Set / reset of the value of channel B to the value of SET VALUE
(only in COUNTER mode)
d, s
INPUT 1 CONFIG
This parameter defines the switching characteristics for the Ctrl� In 1 input�
ACTIVE LOW
Activation in case of "LOW" (static)
ACTIVE HIGH
Activation in case of "HIGH" (static)
RISING EDGE
Activation in case of rising edge
FALLING EDGE
Activation in case of falling edge
INPUT 2 ACTION
This parameter defines the control function of the Ctrl� In 2 input�
See function assignment parameter INPUT 1 ACTION�
INPUT 2 CONFIG
This parameter defines the switching characteristics for the Ctrl� In 2 input�
See activation assignment parameter INPUT 1 CONFIG�
INPUT 3 ACTION
This parameter defines the control function of the Ctrl� In 3 input�
See function assignment parameter INPUT 1 ACTION�