Operating instructions FX460
30
DECIMAL POINT
This setting defines the position of the decimal point�
NO
No decimal point
0000000�0
Decimal point at the specified position
000000�00
Decimal point at the specified position
00000�000
Decimal point at the specified position
0000�0000
Decimal point at the specified position
000�00000
Decimal point at the specified position
00�000000
Decimal point at the specified position
0�0000000
Decimal point at the specified position
WAIT TIME (S)
This parameter defines the period duration of the lowest frequency i�e� the waiting time between two rising
edges at which the device detects the frequency 0 Hz� Frequencies with a period duration that is longer
than the set Wait Time are evaluated as frequency = 0 Hz�
0�00
Display value is retained until a new display value has been determined
0�01
Frequency = 0 Hz in case of frequencies below 100 Hz
���
99�99
Frequency = 0 Hz in case of frequencies below 0�1 Hz
STANDSTILL TIME (S)
This parameter defines the time for the standstill definition� When the frequency is found to be 0 Hz,
standstill is signalled after the time set here (in seconds) has elapsed and the start-up delay is activated
again� Standstill monitoring can be set in the PRESELECTION MENU� STANDSTILL TIME is only useful if
WAIT TIME not equal to 0�00
0�00
Shortest delay time
…
99�99
Longest delay time