CabinetController (CR0301) Runtime System V05
2016-04-21
Configurations
Function configuration of the inputs and outputs
>
4.3.2
Configure outputs
Binary outputs: configuration and diagnosis ....................................................................................... 52
PWM outputs ....................................................................................................................................... 53
3976
Valid operating modes
→ chapter
Possible operating modes inputs/outputs
(
>
Binary outputs: configuration and diagnosis
20884
The following operating modes are possible for the device outputs (
→ data sheet):
• binary output, plus switching (BH), short-circuit proof, overload protected
• binary output with relay (change-over contacts)
• These outputs are not able for diagnosis.
15451
Qn = pin output n
(L) = load
Basic circuit of output plus switching (BH)
for positive output signal
13975
WARNING
Dangerous restart possible!
Risk of personal injury! Risk of material damage to the machine/plant!
If in case of a fault an output is switched off via the hardware, the logic state generated by the
application program is not changed.
► Remedy:
• Reset the output logic in the application program!
• Remove the fault!
• Reset the outputs depending on the situation.
>
Binary outputs: configuration
20890
These outputs are a group of channels with a single specified function.
Permissible values
→ chapter
Possible operating modes inputs/outputs
(
>
Binary outputs: Diagnostics
20888
• These outputs are not able for diagnosis.