Configurations
Function configuration of the inputs and outputs
>
PWM outputs
14705
The following operating modes are possible for the device outputs (
→ data sheet):
• PWM output, plus switching (BH) without diagnostic function
15451
Qn = pin output n
(L) = load
Basic circuit of output plus switching (BH)
for positive output signal
15414
WARNING
Property damage or bodily injury possible due to malfunctions!
For outputs in PWM mode:
• there are no diagnostic functions
• the overload protection OUT_OVERLOAD_PROTECTION is NOT active
9980
NOTE
PWM outputs must NOT be operated in parallel, e.g. in order to increase the max. output current. The
outputs do not operate synchronously.
Otherwise the entire load current could flow through only one output. The current measurement would
no longer function.
>
Availability of PWM
20889
Device
Number of available
PWM outputs
of which current-
controlled (PWMi)
PWM frequency
[Hz]
CabinetController: CR0301, CR0302
4
---
20...250
>
FBs for PWM functions
20891
The following function blocks are available for the PWM function of the outputs:
PWM
(→ page
Initialises and configures a PWM-capable output channel
Definition of the PWM frequency via RELOAD
PWM100
(→ page
Initialises and configures a PWM-capable output channel
Indicate PWM frequency in [Hz]
Indicate mark-to-space ratio in steps of 1 %
PWM1000
(→ page
Initialises and configures a PWM-capable output channel
the mark-to-space ratio can be indicated in steps of 1 ‰