background image

6

Please take into account the required space when using a connection 

cable with an angled socket. For this purpose, align the adapter prior to 

the welding operation to determine the end position of the electrical sensor 

connection. 

 

Screw the sensor into the adapter with the specified tightening torque 

(→ Operating instructions of the sensor).

 

Connect the connection cable to the sensor. 

 

Align the unit.

 

Mark the alignment at the welding adapter and the pipe/tank.

 

Remove the sensor from the adapter. 

 

Carry out the welding operation.

The positioning may change when the sensor is removed and then the 

original orientation is not guaranteed.

 

Fix the adapter in several spots with 

a sufficient adhesive force. Apply the 

fixing points at equal distance opposite 

each other.

 

Apply the welding seams between the 

fixing points opposite each other. 

 

Ensure sufficient intervals between the 

individual sections to avoid glowing 

through or warping of the adapter due 

to overheating.

Summary of Contents for E30503

Page 1: ...Operating instructions Welding adapter E30503 E30508 11447887 00 12 2021 UK UK...

Page 2: ...pliance may result in malfunction or interference Information Supplementary note CAUTION Warning of personal injury Slight reversible injuries may result Contents 1 Preliminary note 2 1 1 Symbols used...

Page 3: ...this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restric...

Page 4: ...refully and according to state of the art technology During welding and the following cooling phase the sensor must not be in place The surfaces must be free from any contamination Welding materials m...

Page 5: ...id overheating of the adapter and observe sufficient cooling phases The sealing area of the adapter must not be damaged by weld spatter or similar The sealing area should be sufficiently protected bef...

Page 6: ...or Align the unit Mark the alignment at the welding adapter and the pipe tank Remove the sensor from the adapter Carry out the welding operation The positioning may change when the sensor is removed a...

Page 7: ...of the thread If the tightening torque is too high do not use any tool but check the thread and replace the adapter if necessary 5 Mount sensor A lubricating paste is required to install the sensor It...

Page 8: ...may impair the seal and lead to the sensor being damaged If the sealing area is damaged replace the adapter 6 Set up Before set up check the tank or pipe for ingress resistance Perform a pressure tes...

Page 9: ...9 UK...