Please take into account the required space when using a connection
cable with an angled socket. For this purpose, align the adapter prior to
the welding operation to determine the end position of the electrical sensor
connection.
►
Screw the sensor into the adapter with the specified tightening torque
(→ Operating instructions of the sensor).
►
Connect the connection cable to the sensor.
►
Align the unit.
►
Mark the alignment at the welding adapter and the pipe/tank.
►
Remove the sensor from the adapter.
►
Carry out the welding operation.
The positioning may change when the sensor is removed and then the
original orientation is not guaranteed.
►
Fix the adapter in several spots with
a sufficient adhesive force. Apply the
fixing points at equal distance opposite
each other.
►
Apply the welding seams between the
fixing points opposite each other.
►
Ensure sufficient intervals between the
individual sections to avoid glowing
through or warping of the adapter due
to overheating.