background image

Operating instructions 

Memory Plug

E30398

704930 / 03

 

08 / 2018

UK

Summary of Contents for E30398

Page 1: ...Operating instructions Memory Plug E30398 704930 03 08 2018 UK ...

Page 2: ...e 9 6 2 Save the parameter set of a sensor continuously 10 6 3 Copy the parameter set of a sensor 11 6 4 Set the parameters of the replacement sensor 12 6 5 Restore the parameter set of a sensor 13 6 6 Configure the memory plug via LR DEVICE 14 6 6 1 Store data on the memory plug 14 6 6 2 Read and edit the data stored on the memory plug 15 6 6 3 Restore the factory setting of the memory plug 15 6 ...

Page 3: ...ols used Instructions Reaction result Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note LED on LED off LED flashes slowly 1 Hz LED flashes quickly 4 Hz LED flickers ...

Page 4: ...f the memory plug is empty no parameter set saved one parameter set can be written to the memory plug once If the memory plug is full a parameter set is saved it is protected against further writing Read Write The memory plug is not protected against overwriting The internal data set is overwritten when the memory plug is connected to a sensor Sensor of the same type Sensors of the same type have ...

Page 5: ... not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qualified personnel authorised by the machine operator Changing parameters during ope...

Page 6: ...k devices It offers the following options Bi directional backup for IO Link V1 1 sensors Bi directional backup for IO Link V1 0 sensors from ifm electronic Preconfiguration as data carrier via PC 4 1 Applications without PC Save the parameter set of a sensor once 6 1 Save the parameter set of a sensor continuously 6 2 Copy the parameter set of a sensor copy to several sensors of the same type e g ...

Page 7: ...the supply voltage After interrupting and restoring the connection between the memory plug and the sensor After saving the parameters all sensor signals are linked through without being changed The output function of the sensor its quality and speed remain unchanged An integrated memory plug does not influence the complete system Recommended operating mode Operation in the Write protected mode is ...

Page 8: ...8 5 Electrical connection The memory plug is an accessory intended for connection to IO Link devices 4 1 3 2 4 1 3 2 Out 2 L L BN BU Out 1 WH BK 1 2 1 Sensor 2 Memory plug ...

Page 9: ...rocess Process terminated Memory plug full Write protected UB Operating voltage P Parameter set The empty memory plug can carry out this process only once It can be reset to the factory setting 6 6 3 Do not install a brand new memory plug before setting the sensor parameters If the memory plug is installed before parameter setting is completed the parameter set defined at this point will be saved ...

Page 10: ...t the memory plug between the sensor and the evaluation unit of the installation Ub P Display when the memory plug is empty Display when the memory plug is full 2 The parameter set of the sensor is changed P P1 Ub P1 3 Disconnect the memory plug from the sensor and connect it again The memory plug reads the changed parameter set P1 and saves it Ub P1 P1 Reading process Process terminated ...

Page 11: ...upply voltage Ub 2 Connect the memory plug with a sensor of the same type The memory plug writes its parameter set to the sensor Ub P Writing process Process terminated 3 Repeat the process with sensors of the same type as often as you wish Ub P This process only works for sensors of the same type sensors with the same IO Link device ID ...

Page 12: ...nect the memory plug to the supply voltage Ub 2 Connect the memory plug with a sensor of the same type If the memory plug is used in the Read Write mode the sensor must have the factory setting If in doubt reset the sensor The memory plug writes its parameter set to the new sensor Ub P Writing process Process terminated Writing process Process terminated ...

Page 13: ...ect the memory plug between the sensor and the evaluation unit of the installation Ub P 2 The parameter set of the sensor is changed P P1 Ub P1 Switch the supply voltage of the installation off and on again The memory plug writes the original parameter set P to the sensor P I 0 Writing process Process terminated ...

Page 14: ...g of a memory plug which contains data appears By clicking on the icon the parameters of the saved device are displayed if this is supported by the respective device Display of the data stored on the memory plug appears after clicking on By clicking on the parameter list of the memory plug is displayed again The icon changes again to The memory plug only provides memory space for the parameters of...

Page 15: ...onnected memory plug is displayed 6 6 3 Restore the factory setting of the memory plug Connect the memory plug to the IO Link master Click on The parameter list of the connected memory plug is loaded into the software Click on The factory setting of the memory plug is restored 6 7 Operation indication No supply voltage Memory plug without saved parameter set in the Write protected mode factory set...

Page 16: ...r in data processing Memory plug in the Write protected mode error in data processing The connected sensor is not of the same type This state remains until a sensor of the same type is connected or the voltage supply is interrupted 6 8 Configuration via teach button 4 1 3 2 4 1 3 2 1 2 4 1 3 2 4 1 3 2 L L BN BU WH BK 3 T 1 Sensor 2 Memory plug 3 Teach button available as accessories order no E3040...

Page 17: ... signalled by a change of the LED display following figures Change from Write protected to Read Write Ub 0 10 13 t s A B A LED display memory plug empty B LED display memory plug full Change from Read Write to Write protected Ub 0 10 13 t s A B A LED display memory plug empty B LED display memory plug full ...

Page 18: ... display memory plug 6 9 Use the memory plug as data carrier Memory plugs can be used as external storage medium When the installation has been set up keep units with saved parameter sets in a safe place 7 Technical data Further technical data and scale drawing at www ifm com ...

Page 19: ... IO Link 1 0 sensor of another manufacturer Sensor not equipped with IO Link Connect an IO Link 1 0 sensor from ifm electronic Connect an IO Link 1 1 sensor The sensor does not support any saving of data Connect a sensor supporting IO Link and saving of data data sheet of the sensor Sensor locked writing impossible Unlock the sensor or connect an unlocked sensor The identification of the connected...

Reviews: