32
Index
Subindex
Name
(object)
Type
Access
Default
value
PDO
mapping
capability
Save
object
value
0x2481
0x00
Lock trig-
ger (trig-
ger for
locking
data on
the ID
tag as
config-
ured in
objects
0x2480
and
0x2481)
bool
wo
-
-
UID filter
Index
Subindex
Name
(object)
Type
Access
Default
value
PDO
mapping
capability
Save
object
value
0x4603
0x00
UID filter
depth
s8
rw
0x00
-
yes
0x4605
0x00
zero ID
filter
depth
s8
rw
0x02
-
yes
9.1.7 Error messages
The device supports a number of error messages that are sent in the event of a
communication, hardware or RFID error. If one of these errors occurs, the error
register (OD index 0x1001) and the error field (OD index 0x1003) are updated.
ID of the emergency message can be changed in the object “COB ID
EMCY” (OD index 0x1014). By setting bit 31 in this object the emergency
messages are deactivated.
The disable time between two emergency messages can be defined via the object
0x1015. The indication is made in steps of 100 µs.