13
Pin assignment
Wiring
M12 connector, A-coded, 5 poles
4
2
1
3
5
1: Shield
2: U+
3: GND
4: CAN high
5: CAN low
The CAN bus connection is almost trouble-free if the following points are
considered:
u
Use cables approved for CAN bus.
u
Terminate the cables with 120 Ω terminating resistors.
Information on available sockets see:
.
8 Operating and display elements
DTM424
DTM425
1
1
1 LEDs green / yellow / red
LED
State
Description
green
on
Operating status pre-operational
flashes every 1.6 s alternating
with yellow LED
Operating status pre-operational and ID tag
detected
flashes every 0.4 s
Operating status operational