Use with RFID read/write heads
LED green
LED yellow
Status
Note
Off
Off
Interface deactivated
Interface in EtherNet/IP master not
configured
Flashes at 2 Hz
Off
Interface activated, antenna off
-
On
Off
Interface activated, tag not in the field
-
On
On
Interface activated, tag in the field
-
Flashes at 8 Hz
Flashes at 8 Hz
Overload, short-circuit or communication
error
-
6.2.6 Special device- LED indications
LED
Status
Note
Green AUX LED on
Yellow AUX LED
flashes at 8 Hz
Yellow IO1 . . .IO4 LEDs
flash at 8 Hz
Device is in the service mode "emergency
system started" .
A firmware update is necessary and can be
executed via the web server .
Green AUX LED on
Yellow AUX LED
flashes at 8 Hz
Green IO1 . . .IO4 LEDs
flash at 8 Hz
Yellow IO1 . . .IO4 LEDs
flash at 8 Hz
Major error, device has to be returned .
Hardware fault or permanent data in the
device are corrupt .
Green AUX LED on
Yellow AUX LED
Flashes at 8 Hz
Yellow IO3 LED
flashes at 8 Hz
Reset to factory settings
-
7 Putting into operation
►
Connect the device according to the operating instructions .
> After connecting the operating voltage, the unit is ready for use .
The green power supply LEDs of the read/write heads will light up after enabling the corresponding
module in the module configuration .