9 Maintenance, repair and disposal

The unit is maintenance-free.

u

Contact ifm in case of malfunction.

u

Do not open the housing as the unit does not contain any components which can be maintained by
the user. The unit must only be repaired by the manufacturer.

u

Clean the device using a dry cloth.

u

Dispose of the unit in accordance with the national environmental regulations.

Summary of Contents for ANT430

Page 1: ...Operating instructions RF identification system ANT430 ANT431 Read write head 11476238 00 08 2022 GB ...

Page 2: ... Function 7 5 1 ID tags 7 5 2 Device overview 7 6 Installation 8 6 1 Notes on the unit installation 8 6 2 Avoiding interference 8 6 3 Mechanical design 8 6 4 Install device 8 6 5 Mounting distances 9 6 6 Positioning of the ID tags 10 7 Electrical connection 12 7 1 Wiring 12 8 Operating and display elements 13 9 Maintenance repair and disposal 14 10 Approvals standards 15 Glossary 16 ...

Page 3: ...oss reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright information All rights reserved by ifm electronic gmbh No part of these instructions may be reproduced and used without the consent of ifm electronic gmbh All product names pictures companies or other ...

Page 4: ...nded purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qu...

Page 5: ... use The read write head reads and writes ID tags without contact For use the read write head must be connected to the DTE10x evaluation unit The data is converted into digitally coded values and provided to the evaluation unit ...

Page 6: ... Items supplied Read write head The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using components from other manufacturers ...

Page 7: ... generates a magnetic field which partly penetrates the antenna coil of the ID tag A voltage is generated by induction that supplies the data carrier with energy The device supports ID tags according to ISO 15693 5 2 Device overview ANT430 Article number ANT430 Function Read write head Type designation DTRHF IBRWIDUS03 Type M30 flush mountable ANT431 Article number ANT431 Function Read write head ...

Page 8: ... electrical field with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency converters and switched mode power supplies If there are other devices in the same frequency band in the vicinity u The mounting distances between the devices should be as large as possible ...

Page 9: ...ANT430 ANT431 9 ANT430 Fig 3 Flush mounting ANT431 Fig 4 Non flush mounting 6 5 Mounting distances ANT430 Operating mode Distance side A Distance front B For reading and writing 50 mm 100 mm ...

Page 10: ... For installation in or on metal use the ID tags provided for this purpose Position the ID tag in the area of the sensing face When doing so the angle of aperture and the operating distance must be adhered to Data sheet of the device ANT430 D Fig 5 Position the ID tag u Align the ID tag on the central axis of the antenna of the device ID tag Type Distance read write head D in metal Distance read w...

Page 11: ...ID tag u Align the ID tag on the central axis of the antenna of the device ID tag Type Distance read write head D in metal Distance read write head D in plastic E80371 45 mm 45 mm The indications in the table apply to static read write operations ...

Page 12: ...ower before connecting the device 7 1 Wiring u Connect the unit to a DTE10x evaluation unit via the M12 connector w Voltage is supplied via the evaluation unit Pin assignment Wiring 4 1 3 L 1 3 4 L DATA Information on available sockets see www ifm com Cables with the following characteristics are suitable for the connection Length Ohmic resistance feed return line Effective cable capacity 20 m max...

Page 13: ...oltage OK off operating voltage missing flashing slowly deactivated yellow on permanently ID tag detected on pulse ID tag read written successfully flashing quickly error when reading writing on ID tag off no ID tag in the field faulty ID tag in the field invalid ID tag in the field green and yellow flashing alternately error in communication or device fault ...

Page 14: ...in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device using a dry cloth u Dispose of the unit in accordance with the national environmental regulations ...

Page 15: ... and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for approval Package insert of the device and documentation ifm com ...

Page 16: ... used to identify objects A read write device is used to read the ID tag via a high frequency radio signal An ID tag consists of an antenna an analogue circuit for receiving and transmitting transceiver a digital circuit and a non volatile memory ...

Reviews: