IO-Link Master with IoT Interface DataLine 8 Ports IP 65 / IP 66 / IP 67
37
>
9.2.4
IoT interface: Configure security mode
54683
The access to the IoT interface of the IO-Link master can be protected with a security mode:
Sub-structure:
iotsetup
Available data points:
Name
Description
Access
../security/securitymode
active security mode
rw
../security/password
Password for authentication (Base64 coded)
w
rw ... read and write
w ... write only
Valid character set for the Base64 coding / decoding of the password: UTF-8
Online tool for coding / decoding:
>
Note: Security mode
54684
The security mode enables restricting access to the IO-Link master and the connected IO-Link devices
from the IT network. In the activated security mode, the following restrictions apply:
Access only with authentication (password-protected user account)
Access only via secure https connection (Transport Layer Security - TLS)
The security mode only protects the access to the device via the IoT interface.
The standard value for users is: administrator
The set password cannot be read with getdata.
The current status of the security function can be read with the getidentity service (
→
Service:
getidentity
(
For the authentication, the user must additionally provide the POST requests with a valid user name
and password in the field "auth". The user name and the password will be shown as Base64-coded
character strings (
→
Example: Request with authentication
(
The following requests can be done if the security mode is enabled, also without authentication:
/getidentity
/deviceinfo/vendor/getdata
/deviceinfo/productcode/getdata