background image

Video door phone set

Assembly and operating manual

Summary of Contents for Bastion Draco

Page 1: ...Video door phone set Assembly and operating manual...

Page 2: ...eder 4 4 Before the assembly 5 Specify the places where elements are to be mounted 5 Electric installation of video door phone 5 Block connection diagrams 6 5 Assembly and connecting elements of video...

Page 3: ...level The external panel is powered with video door phone voltage Vcc and GND clamps on the external panel should not be connected to an external feeder Video door phone elements should be connected t...

Page 4: ...olour camera camera illuminator loudspeaker microphone and release button The panel is wall mounted The panel is equipped with a transmitter releasing electro catch after the button on the monitor is...

Page 5: ...not include in the set Electro catch of 12V AC 1A max should be used in the video door phone While selecting the electro catch take into account the mechanical build and type left or right of the doo...

Page 6: ...external panel at the distance exceeding 60 m from monitor with the appropriate cable sections Mount the feeder inside in a place not exposed to humidity Feeder should be mounted on a DIN rail in the...

Page 7: ...re 4 Connection of Draco video door phone single line diagram MVC 6501 ZS 15 2 230V 2 4 Optional connecting second monitor MVC 6501 BVC 6501 12V AC 1A feeder ZS 15 J103 J100 Electro catch Wiring in ex...

Page 8: ...nitor MVC 6501 MVC 6501 230V AC 15V DC 0 8A 230V AC 12V AC 1A Vcc Gnd audio video red black violet white Vcc Gnd audio video red black violet white Vcc Gnd audio video red black violet white Vcc Gnd a...

Page 9: ...luded in the set for J100 and J103 sockets to the wiring in accordance with the diagram soldering them to the wiring Secure the soldered places and isolated wiring cables against short circuit using s...

Page 10: ...onal monitor is mounted the doorbell signal and the image from the camera will appear on two monitors Push button conversation see Figure 1 to launch voice communication In the case of two monitors mo...

Page 11: ...ctro catch at any time during the conversation by pushing the button on the screen The electro catch operates for up to ca 5 s Its operation period does not depend on the length of button pushing The...

Page 12: ...te collection units INSTRUCTION ON ENVIRONMENT PROTECTION List of collecting units of used Laskomex equipment is available on www laskomex com pl website or telephone No 42 671 88 68 Product packing s...

Reviews: