12.8 Activate/deactivate result output
Command
p <digit>
Type
Action
Reply
*
Successful execution
!
● No active application .
● <digit> contains incorrect value .
● The device is in an invalid state .
Note
<digit> is either 0 or 1 .
1 enables the result output .
0 disables the result output .
12.9 Transmit the image to the device for evaluation
Command
i <length><image data>
Type
Action
Reply
*
Normal case
?
Invalid length
!
● No application at present .
● Application is being edited .
● The image format (BMP, RAW, etc .) does not meet the specifi-
cations .
● Invalid image contents (image size, internal image head data) .
Note
<length>: character string with exactly 9 digits, interpreted as decimal number it
indicates the length of the following image data in bytes .
Image data format according to setting in the operating program . The image
must be available with a resolution of 640x480 . With the Raw image format, each
pixel is coded with an 8 bit value, the bmp must be available in 8 bit format .