8.4 Lock / unlock sensor
Lock sensor
► Keep [Mode/Enter] and [Set] pressed simultaneously for 10 s .
> Display changes to uLoc .
► Press [Set] .
► Display changes to Lock .
► Confirm with [Mode/Enter] .
> The sensor is locked .
Unlock the sensor
► Keep [Mode/Enter] and [Set] pressed simultaneously for 10 s .
> Display shows Lok1, changes to Lock after 10 s .
► Press [Set] .
> Display changes to uLoc .
► Confirm with [Mode/Enter] .
The sensor is unlocked, display changes to "run" .
8.4.1 Reset device to factory settings
► Activate the parameter "rES" .
► Press [SET] > 5 s .
8.5 Parameter setting via PC operating program
The PC operating program is described in a separate document → Programming
manual E2D200 .