S
AFETY
C
ONTROLLER
CR7505
PAGE
30
CR7505
Characteristics of the inputs
Digital/analogue inputs
(B
L
, A)
■
Voltage inputs
▲
%IW03...10
input voltage
0...10/32 V
▲
%IX0.00...07
resolution
12 bits
can be configured as ...
precision
± 1.0% FS
input resistance
50/30 k
Ω
input frequency
50 Hz
■
Current inputs
input current
0/4...20 mA
resolution
12 bits
precision
± 1.0% FS
input resistance
400
Ω
input frequency
50 Hz
■
Digital inputs for positive sensor signals
switch-on level
0.7 U
B
switch-off level
0.4 U
B
input resistance
30 k
Ω
input frequency
50 Hz
Digital inputs
(B
L
)
■
Digital inputs for positive sensor signals
-- %IX0.08...11
switch-on level
0.43...0.73 U
B
can be configured as ...
switch-off level
0.29 U
B
input resistance
3.21 k
Ω
input frequency
50 Hz
Digital inputs
(B
L
, I
L
)
■
Digital inputs for positive sensor signals
▲
%IX0.12...15
switch-on level
0.7 U
B
can be configured as ...
switch-off level
0.4 U
B
input resistance
2.86 k
Ω
input frequency
50 Hz
■
Frequency inputs for positive sensor signals
evaluation with integrated comparator
switch-on level
0.43...0.73 U
B
switch-off level
0.29 U
B
input resistance
2.86 k
Ω
input frequency
max. 50 kHz
Digital inputs
(B
L
, I
L
)
■
Digital inputs for positive sensor signals
▲
%IX1.04...07
switch-on level
0.7 U
B
can be configured as ...
switch-off level
0.4 U
B
input resistance
3.21 k
Ω
input frequency
50 Hz
■
Frequency inputs for positive sensor signals
evaluation with integrated comparator
switch-on level
0.43...0.73 U
B
switch-off level
0.29 U
B
input resistance
3.21 k
Ω
input frequency
max. 1 kHz
Test input
The test input must be active when e.g. software is to be downloaded in the controller
(pin 24 to VBB
S
, 10...32 V DC).
Safety-related outputs (MODE byte OUT_Safety) cannot be used with the test input
active. Deactivate the test input and carry out a reset to make them available again.
(Reset = switching on / off of the controller)
During operation of the machine the test input must be connected to GND.
input resistance
3.21 k
Ω
wiring see page 5
Observe the special notes in the documentation "Supplement to the system manual,
SafetyController R360".
ifm electronic gmbh • Teichstraße 4 • 45 127 Essen
16.10.2006
We reserve the right to make technical alterations without prior notice.
CR7505 / page 3
Abbreviations
▲
= safety-related
--
= not safety-related
A
= analogue
B
H
= binary High Side
B
L
= binary Low Side
FRQ/CYL = frequency inputs
I
H
= pulse High Side
I
L
= pulse Low Side
PWM
= pulse width modulation
PWM
I
= current-controlled output
%IW...
= IEC address for analogue input
%IX...
= IEC address for binary input
%QX...
= IEC address for binary output