Integrated access control with an electric door strike
Rex
Normally
Open switch
Alarm
shunt
Forced
Door
Door
Ajar
Tech Tip:
This prodct will operate off of
12 through 24 VDC only
. IEI
prefers filtered and regulated
power. Part # PWR TMPR 12
Input loop common = WO
Door position input = W
Timed egress = BR
P5
NO C NC NO C NC NO C NC
Programming
switch
Electric door strike
(fail secure)
Forced door & Door ajar functions require a normally closed
set of door contacts
SW1
Normally closed
door contacts
*
*
To alarm panel
Closed loop
V-
V+
Siren
Sounder
+ - NC C NO
3
2
1
Part # EZ REX
White Orange = W/O
White = W
Brown = BR
W/O
W
BR
PWR
+
-
Note 1:
If door contact is not being used the white with orange stripe and the white
wire should be spliced together.
Note 2:
If power keypad and lock with same power source, the lock
voltage must match the power supply voltage.
P5
12 – 15VDC
only
15 – 24 VDC
only
3
2
1
3
2
1