Trouble shooting 

 

 
 
 
 
 
 
 

 

Section 6: Trouble Shooting.

 

 

Refer to this section if the SSiLW is not responding correctly to the operation outlined in this 
instruction manual.  The SSiLW has been designed to operate with 5 - 12 VDC only.  Verify that the 
voltage powering this keypad is within these parameters. 
 

Situation 1:  

The Master code is not allowing access to the programming mode. 

 

Reason: 

There are a few reasons that this situation could occur.  The most common is 
that the Master code was programmed incorrectly.  That is to say that someone 
used the incorrect user number to add a user code.  The Master code is always 
kept in memory with user number "1". 

 

The other reason this could happen is that the code was simply forgotten. 

Solution: 

Power down the keypad, connect the White / yellow to blue and brown wires on 
the SSiLW wire harness and power back up.  The yellow LED will be flashing 
indicating that the keypad is now in programming mode.  Change the Master 
code by press 1 # (New Master Code) * (Repeat Master Code) * *.  When 
finished with programming, power down the unit, separate the blue and brown 
wires from the white yellow on the SSiLW harness and power back up.  The 
keypad is now ready to use. 

 

Situation 2: 

No LED's are lit on the keypad 

 
 Reason: 

Power is not reaching the keypad. 

Solution: 

With a meter check the voltage connection at the SSiLW keypad on the Red & 
Black wires.  Confirm that there is actually voltage at the keypad.  If there is no 
voltage reading at the keypad, use the meter on the power supply to verify that 
voltage is leaving the power supply.  If there is no voltage coming out of the 
power supply, call the manufacturer of that power supply.  If there is voltage at 
the power supply, but not at the keypad, use the meter to test each of the wires 
for a break in the wire. 

 
 
 
 
 
 
 

 
If this product does not seem to operate properly, please call our 
Technical support department Monday through Friday 8:00 am 
through 7:00 pm eastern standard time, at 1-800-733-9502 & 1- 800 –
343 - 9502 EXT 3.  We understand your time is valuable and by calling 
Technical support we assure that we will be as quick and accurate as 
we possibly can. 

Thank you for choosing IEI 

Summary of Contents for SSW-iLW

Page 1: ...www ieib com Page 1 of 13 6050723 Rev 1 0 Open Technology SSW iLW ...

Page 2: ...st Open the box and inside you will find 1 SSiLW keypad 1 6 Conductor wire harness 2 1 1 4 black socket cap flat head machine screws 2 1 1 4 black Phillips flat head sheet metal screws 1 11 64 Allen wrench 1 Installation Manual for SSiLW Also Included when using model 212 SiL Programming controller Four conductor wire harness 1 Three conductor wire harness 4 Command and control features and progra...

Page 3: ... 3 8 x 5 1 8 x 5 8 Wiring the design series SSiLW to an IEI controller requires a 4 conductor stranded shielded cable between the keypad and controller Maximum distance between the two are as follows 22 AWG stranded 250 feet 20 AWG stranded 500 feet 18 AWG stranded 1000 feet At the controller connect the four conductor wire harness to the four pin connector labeled p2 on the controllers relay boar...

Page 4: ... loop common W O Door position input W Timed egress BR Note 1 If no door contact is being used it must be jumped closed White Orange White NO C NC NO C NC NO C NC NC C NO Magnetic door lock Fail safe Forced door Door ajar functions require a normally closed set of door contacts Note 2 If powering the keypad and lock with same power supply as shown in diagram lock voltage must match power supply vo...

Page 5: ...itch Forced door Door ajar functions require a normally closed set of door contacts Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced together Note 2 If power keypad and lock with same power source the lock voltage must match the power supply voltage SW1 Normally closed door contacts To alarm panel Closed loop V V Siren Sounder NC C NO 3 2 1...

Page 6: ...Door position input W Timed egress BR NO C NC NO C NC NO C NC Programming switch Forced door Door ajar functions require a normally closed set of door contacts 3 2 1 Part EZ REX Electric door strike fail secure White Orange W O White W Brown BR W O W BR PWR SW1 P5 Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced together Note 2 If power key...

Page 7: ...NO C NC Programming switch Electric door strike fail secure Forced door Door ajar functions require a normally closed set of door contacts SW1 Normally closed door contacts To alarm panel Closed loop V V Siren Sounder NC C NO 3 2 1 Part EZ REX White Orange W O White W Brown BR W O W BR PWR Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced to...

Page 8: ...ed Series Press 91 3 0 Secured Series Recording status OUT Press 91 4 1 Secured Series Recording Status IN Press 91 4 0 Below for SS iLW Only Wiegand Red led enable Press 91 5 1 Wiegand Red led disable Press 91 5 0 Wiegand Red led state High Press 91 6 1 Wiegand Red led state Low Press 91 6 0 Wiegand Green led enable Press 91 7 1 Wiegand Green led disable Press 91 7 0 Wiegand Green led state High ...

Page 9: ...commended that you perform the self test mode While the unit is powered up enter the following on the SSiLW keypad 7890 123456 If all 12 key presses have been verified the keypad will enter self test mode The LED s will alternate three times and the sounder will beep three times followed by a flickering yellow LED Press any key to return to normal operation System Defaults The SS iLW series keypad...

Page 10: ...r code by press 1 New Master Code Repeat Master Code When finished with programming power down the unit separate the blue and brown wires from the white yellow on the SSiLW harness and power back up The keypad is now ready to use Situation 2 No LED s are lit on the keypad Reason Power is not reaching the keypad Solution With a meter check the voltage connection at the SSiLW keypad on the Red Black...

Page 11: ...Series and sets it in Hub Front End mode Red 5 12 VDC Black GND Wht Blk Wht Yel Blue Brown Defaults Design Series and sets it in Wiegand 26 bit mode Red 5 12 VDC Black GND Wht Blk DAO Wht Yel DA1 Blue LED1 Brown Not used If the local program code is lost or forgotten power down the system connect the wire harness as shown below then power the system up Change your local program code then power dow...

Page 12: ... to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI WILL not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in or malfunction of it s products This warranty shall expire two years from mfg date code found on micro processor for Door Gard Keypads Except as stated above IEI mak...

Page 13: ...www ieib com Page 13 of 13 6050723 Rev 1 0 Note Use this template to help d rill holes for easy installation Weep holes ...

Reviews: