Defaulting the SSiLW keypad
If the four data wires are shorted in one of the two configurations shown below on power up, the
option will be set. Remove power after you hear the 3 beeps then reconnect the data lines to their
proper working configuration.
System Defaulting the Design SSiLW wiring
Defaults Design Series and sets it in Hub Front End mode
Red - +5 – 12 VDC
Black - GND
Wht/Blk
Wht/Yel
Blue
Brown
Defaults Design Series and sets it in Wiegand 26 bit mode
Red +5 – 12 VDC
Black - GND
Wht/Blk (DAO)
Wht/Yel (DA1)
Blue ( LED1 )
Brown ( Not used )
If the local program code is lost or forgotten, power down the system, connect
the wire harness as shown below then power the system up. Change your local
program code then power down the system and restore the wire harness to its
original configuration and power back up.
Red - +5 – 12 VDC
Black - GND
Wht/Blk - No connection
Wht/Yel
Blue
Brown