NANO-PV-D510A User Manual
Page 148
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE W_LOOP
;No,
restart
the
application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Summary of Contents for NANO-PV-D510A
Page 15: ...NANO PV D510A User Manual Page 1 Chapter 1 1 Introduction...
Page 18: ...NANO PV D510A User Manual Page 4 Figure 1 3 NANO PV D510A Dimensions mm...
Page 22: ...NANO PV D510A User Manual Page 8 Chapter 2 2 Unpacking...
Page 26: ...NANO PV D510A User Manual Page 12 Chapter 3 3 Connectors...
Page 51: ...NANO PV D510A User Manual Page 37 Chapter 4 4 Installation...
Page 76: ...NANO PV D510A User Manual Page 62 Chapter 5 5 BIOS...
Page 126: ...NANO PV D510A User Manual Page 112 Appendix A A BIOS Options...
Page 130: ...NANO PV D510A User Manual Page 116 Appendix B B One Key Recovery...
Page 136: ...NANO PV D510A User Manual Page 122 Figure B 3 Partition Creation Commands...
Page 153: ...NANO PV D510A User Manual Page 139 Appendix C C Terminology...
Page 157: ...NANO PV D510A User Manual Page 143 Appendix D D Digital I O Interface...
Page 160: ...NANO PV D510A User Manual Page 146 Appendix E E Watchdog Timer...
Page 163: ...NANO PV D510A User Manual Page 149 Appendix F F Compatibility...
Page 166: ...NANO PV D510A User Manual Page 152 Appendix G G Hazardous Materials Disclosure...