NANO-HM651 EPIC SBC
Page 146
NOTE:
The following discussion applies to DOS. Contact IEI support or visit the IEI
website for drivers for other operating systems.
The Watchdog Timer is a hardware-based timer that attempts to restart the system when it
stops working. The system may stop working because of external EMI or software bugs.
The Watchdog Timer ensures that standalone systems like ATMs will automatically
attempt to restart in the case of system problems.
A BIOS function call (INT 15H) is used to control the Watchdog Timer.
INT 15H:
AH – 6FH Sub-function:
AL – 2:
Sets the Watchdog Timer’s period.
BL:
Time-out value (Its unit-second is dependent on the item “Watchdog
Timer unit select” in CMOS setup).
Table E-1: AH-6FH Sub-function
Call sub-function 2 to set the time-out period of Watchdog Timer first. If the time-out value
is not zero, the Watchdog Timer starts counting down. When the timer value reaches zero,
the system resets. To ensure that this reset condition does not occur, calling sub-function
2 must periodically refresh the Watchdog Timer. However, the watchdog timer is disabled
if the time-out value is set to zero.
A tolerance of at least 10% must be maintained to avoid unknown routines within the
operating system (DOS), such as disk I/O that can be very time-consuming.
Summary of Contents for NANO-HM651
Page 15: ...NANO HM651 EPIC SBC Page 1 Chapter 1 1 Introduction ...
Page 22: ...NANO HM651 EPIC SBC Page 8 Chapter 2 2 Unpacking ...
Page 26: ...NANO HM651 EPIC SBC Page 12 Chapter 3 3 Connectors ...
Page 51: ...NANO HM651 EPIC SBC Page 37 Chapter 4 4 Installation ...
Page 76: ...NANO HM651 EPIC SBC Page 62 Chapter 5 5 BIOS Screens ...
Page 107: ...NANO HM651 EPIC SBC Page 93 Appendix A A BIOS Options ...
Page 110: ...NANO HM651 EPIC SBC Page 96 Appendix B B One Key Recovery ...
Page 118: ...NANO HM651 EPIC SBC Page 104 Figure B 5 Partition Creation Commands ...
Page 152: ...NANO HM651 EPIC SBC Page 138 Appendix C C Terminology ...
Page 156: ...NANO HM651 EPIC SBC Page 142 Appendix D D Digital I O Interface ...
Page 159: ...NANO HM651 EPIC SBC Page 145 Appendix E E Watchdog Timer ...
Page 162: ...NANO HM651 EPIC SBC Page 148 Appendix F F Hazardous Materials Disclosure ...