If an LCD module is connected to the iCON100,
a.
Apply DC power to the Controller and set the DIP SW #8 to the OFF position. <Figure 5>
b.
The LCD displays “Turn on DIP 8 Turn OFF Power…”. <Figure 6>
c.
Power off the Controller and return the DIP SW #8 to the ON position. Then, power on the Controller
again. <Figure 7>
<Figure 5> <Figure 6> <Figure 7>
▶
If an LCD module is NOT connected to the iCON100,
a.
A Apply DC power to the Controller and set the DIP SW #8 to the OFF position. <Figure 5>
b.
Wait for about 2 seconds. Then, power off the Controller and return the DIP SW #8 to the ON
position. Then, power on the Controller again. <Figure7>
2.
FINGER006/007 Series, 505 Series, FACE006/007 Series
1) Battery Switch Setting
Turn on the backup battery switch as shown below.
2) Initialization
▶
Hard Initialization:
1.
Power off the product, and connect the yellow and cyan wires
of the product to the GND. Turn on the power.
(See the diagram above.)
2.
The LCD displays the ‘SYS INITIALIZE’ screen. To begin
initialization, press the button.
3.
After the “Master Password” screen appears, enter the
password. (The default password is “3141”)
Turn on DIP 8
Turn OFF Power…
SYS I NIT IALI ZE
1 – Yes, 0 - No
Master Password
[ _ _ _ _ ]
1
12V
POWER
Red (+)
Cyan
Pink
Black (-)
Summary of Contents for FINGER007 Series
Page 1: ......