VP5300 Electrical Requirements
Voltage requirement:
9VDC (minimum) is recommended, to 12V maximum.
3.1.
Power Consumption
•
Stop Mode (without NFC)
≦
85uA
•
Stop Mode (with NFC)
≦
85uA
3.2.
Current Draw
VP5300 OPERATING MODE: 12VDC
9VDC
Normal
83mA
115mA
MSR
86mA
120mA
ContactLess
190mA
264mA
Contact EMV
85mA
125mA
Lan Connection
120mA
165mA
L100
150mA
200mA
ContL100
245mA
357mA
ContL100+ Lan
connection
285mA
410mA
ContL100+Lan
connection
+BuzzerX2
325mA
470mA
L80
123mA
156mA
ContL80
231mA
305mA
ContL80+ Lan
connection
254mA
334mA
ContL80+Lan
connection
+BuzzerX2
275mA
352mA
Sleep Mode, NFC off
Sleep Mode, NFC on
47
μ
A
490
μ
A
88
μ
A
500
μ
A
Stop Mode, NFC off
42
μ
A
83
μ
A
Stop Mode, NFC on
560
μ
A
490
μ
A
Battery:
The unit contains a small lithium battery to power the Real Time Clock and certain anti-
tamper features. This battery has a shelf life of five years. The battery is not user-replaceable. Do not
attempt to open the VP5300 for any reason; this will trigger the anti-tamper features, causing the
unit to become inoperable. If battery replacement is required, return the VP5300 to ID TECH. Contact
for more information.