![IDTECH Vivopay Neo 2 Developer'S Manual Download Page 484](http://html.mh-extra.com/html/idtech/vivopay-neo-2/vivopay-neo-2_developers-manual_618786484.webp)
NEO 2 Interface Developer’s Guide
484
Symbol
Value
Note
&
0x26
!
0x21
¡
0xA1
?
0x3F
¿
0xBF
*
0x2A
+
0x2B
§
0xA7
¢
0xA2
$
0x24
•
0xB7
/
0x2F
\
0x5C
#
0x23
-
0x2D
%
0x25
½
0xBD
¼
0xBC
19.4.4.
Numeric Entry
Only IDG commands requiring digital input can make numeric entries display. A user CANNOT call
Add
Object to Screen (61-07)
to display a numeric entry widget.
If the user UI shows a numeric entry screen, the numeric entry is kept until the user updates the UI.
If the system UI shows a numeric entry screen, the numeric entry is closed after the end of the
numeric entry session.
19.4.5.
Extended Status Codes
Status Code
Status
00h
OK
01h
Incorrect Header Tag
02h
Unknown Command
03h
Unknown Sub-Command
04h
CRC Error in Frame
05h
Incorrect Parameter
06h
Parameter Not Supported
07h
Mal-formatted Data
08h
Timeout
0Ah
Failed / NACK
0Bh
Command not Allowed
0Ch
Sub-Command not Allowed
0Dh
Buffer Overflow (Data Length too large for reader buffer)
0Eh
User Interface Event
10h
Need clear firmware (apply in boot loader only)
11h
Communication type not supported, VT-1, burst, and so on.