![IDTECH Vivopay Neo 2 Developer'S Manual Download Page 332](http://html.mh-extra.com/html/idtech/vivopay-neo-2/vivopay-neo-2_developers-manual_618786332.webp)
NEO 2 Interface Developer’s Guide
Copyright © 2019, International Technologies & Systems Corporation. All rights reserved.
332
8.21.6.
Retrieve Log (4C-06)
Use this command to output log saved in file and ring buffer.
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14
Byte 15
Header Tag &
Protocol
Version
Command
Sub-
Command
Data Length
(MSB)
Data Length
(LSB)
CRC (MSB)
CRC (LSB)
ViVOtech2\0
4Ch
06h
00h
00h
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12 Byte 13
Byte 14 …
Byte 14+n
Byte 15 +
n
Byte 16 +
n
Header Tag &
Protocol
Version
Command Status Code
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC
(MSB)
CRC (LSB)
ViVOtech2\0
4Ch
See
Log data
Note:
•
Because the maximum output data length is 1024 bytes, you may call this command
several times to retrieve whole log from file and ring buffer.
•
A response with 0 data length indicates that all log data has been output.
•
You can try to retrieve a log from the beginning again after receiving a response 0 data
length response.