NEO 2 Interface Developer’s Guide
Copyright © 2019, International Technologies & Systems Corporation. All rights reserved.
164
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command Status Code
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (MSB)
CRC
(LSB)
ViVOtech2\0
60h
See Status
Code Table
See Response
Frame Data
Format
Response Frame Data Format:
<TagCounterL> <TagCounterH> <TLV1> <TLV2>…<TLVn>
Note:
•
<TagCounterL> <TagCounterH> is the number of <TLV> tags.
•
If Terminal Data does not exist, status code is 0x60.
8.4.7.
Contact Remove Terminal Data (60-05)
Use this command to delete terminal data.
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12 Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command
Sub-
Command
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (LSB)
CRC (MSB)
ViVOtech2\0
60h
05h
00h
00h
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command Status Code
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (MSB)
CRC
(LSB)
ViVOtech2\0
60h
See Status
Code Table
See Response
Frame Data
Format
If Terminal Data does not exist, status code is 0x60.