Review Settings
<STX><R><1Fh><ETX><CheckSum>
This command does not have any <FuncData>. It activates the
review settings command. MiniMag sends back an <ACK> and
<Response>.
<Response> format:
The current setting data block is a collection of many function-
setting blocks <FuncSETBLOCK> as follows:
<STX><FuncSETBLOCK1>…<FuncSETBLOCKn><ETX><CheckSum>
Each function-setting block <FuncSETBLOCK> has the following
format:
<FuncID><Len><FuncData>
Where:
<FuncID> is one byte identifying the setting(s) for the function.
<Len> is a one byte length count for the following function-setting
block <FuncData>
<FuncData> is the current setting for this function. It has the same
format as in the sending command for this function.
<FuncSETBLOCK> are in the order of their Function ID<FuncID>
MSR Reading Settings
Turn the MiniMag on or off. If the reader is disabled, no data will be
sent out to the host.
<STX><S><1Ah><01h><MSR Reading
Settings><ETX><CheckSum>
MSR Reading Settings:
“0”
MSR Reading Disabled
“1”
MSR Reading Enabled
Decoding Method Settings
The MiniMag can support three kinds of decoded directions.
<STX><S><1Dh><01h><Decoding Method
Settings><ETX><CheckSum>
Decoding Method Settings:
“0”
Raw Data Decoding in Both Directions
“1”
Decoding in Both Directions
“2”
Moving Stripe Along Head in Direction of Encoding
“3”
Moving Stripe Along Head Against Direction of
Encoding
With the bi-directional method, the user can swipe the card in either
direction and still read the data encoded on the magnetic stripe.
Otherwise, the card can only be swiped in one specified direction to
read the card.