Communication Parameter Selections
Baud Rate Setting
<STX><S><41h><01h>< Baud Rate Setting><ETX><CheckSum>
<Baud Rate Setting>:
“3”
2400 bps
“4”
4800 bps
“5”
9600 bps
“6”
19200 bps
Parity Setting
<STX><S><43h><01h>< Parity Setting><ETX><CheckSum>
<Parity Setting>:
“0”
None
“1”
Even
“2”
Odd
“3”
Mark
“4”
Space
Data Bit Setting
<STX><S><42h><01h>< Data-Bit Setting><ETX><CheckSum>
<Data-Bit Setting>:
“0”
8 Bits
“1”
7 Bits
Start/End Sentinel And Track 2 Account Number Only
The MiniMag can be set to either send, or not send, the Start/End
sentinel, and to send either the Track 2 account number only, or all
the encoded data on Track 2. (The Track 2 account number setting
doesn’t affect the output of Track 1 and Track 3.)
<STX><S><19h><01h><SendOption><ETX><CheckSum>
<Send Option>
“0”
Not send start/end sentinel and send all data on Track 2
“1”
Send start/end sentinel and send all data on Track 2
“2”
Not send start/end sentinel and send account number on
Track 2
“3”
Send start/end sentinel and send account number on Track 2
11
12