5.3 Stopping the stamp machine
(while running)
There are 3 ways to stop the stamp machine:
Push one of the “Emergency Stop” buttons (causes e-stop). Only For Urgent Stops
Open one of the guard doors (causes e-stop). Only For Urgent Stops
Press the “Stop” button on the touch screen (stops auto cycle). For Normal stops before
pressing the emergency stop or opening a guard door.
The E-Stop removes power (air and electric) from most of the machine. The glue tower and
stamp head sensors will still have power. After using the “E-Stop”, the operator
must restart
the
VL-HP by clearing the source of the error. You should ALWAYS press the E-Stop button before
opening and/or reaching into the machine. As the E Stop button is pressed the air should be
heard escaping from the machine. All cylinders should be free. If the air escaping is not heard
or there indication of air remaining in the system the problem most be resolved before reaching
passed any guarding.
If you need to open the front doors of the machine for access inside, simply lift up on the door
handle and slide the door up and back. The doors each have a magnetic safety interlock which
initiates an “Emergency Stop” whenever the door is opened.
Opening one of the front doors allows access to the machine. The doors each have a safety
interlock which performs an E-Stop whenever the door is opened. All doors must be fully closed
before the VL-HP will be able to run again.