Setting the digital display
The Viroxid
®
Habitat 3 can be set using the display on the front of the
device. The display can be easily operated with just the one button.
Drawing 7 of these instructions for use shows how to navigate through
the menu. Details on each setting can be found below.
After the start-up, the validity of the time will be tested first. When you
switch the device on for the first time, the software will automatically
take you to the ‘clock set mode’. You can set the current time here.
You can set the hours by pressing the button briefly. The time is dis-
played in a 24-hour format. After the hours have been correctly set,
you can jump to the minute setting by pressing the button for 3 sec-
onds. You can now set the minutes by briefly pressing the button as
many times as necessary. As soon as the time has been correctly set,
wait 5 seconds. The software will automatically save the time, and the
dot next to the second digit will blink every second.
‘8000.’: If you press the button once in the rest position, the operating
hours will be displayed. The display will automatically start from the fac-
tory setting of the timer, i.e. 8,000 hours.
The UV-C lamp operates at 100% radiation for up to 8,000 hours. After
8,000 operating hours, the UV-C radiation will weaken, and may be
insufficient to obtain the desired results. If the device is switched off and
then on again, the hour counter will start counting backwards from the
value it had when it was switched off.
‘t-LO’: If you press the button twice in the rest position, the indication
‘t-LO’ will appear. This means: The low position of the air circulation. The
ventilator is hereby set for an air circulation of 25 m
3
per hour, and the
device is virtually silent. The low air circulation can be set by pressing
and holding the button for 3 seconds while the ‘t-LO’ indication is visi-
ble on the display. When the hour digits start blinking, you can set the
hour at which the device should switch to the low position. The hours
will start counting upwards as soon as the button is pressed. You can set
the desired hour by briefly pressing the button again. The minutes will
start blinking 5 seconds after you have released the button, and you
can then set the minutes. The settings will be saved, and the current
time will be displayed after 5 seconds.
‘t-HI’: The ‘t-HI’ indication will appear if you press the button three times
in the rest position. This means: The high position of the air circulation.
The ventilator hereby is set for an air circulation of 50 m3 per hour. The
high air circulation can be set by pressing and holding the button for
3 seconds when the indication ‘t-HI’ is visible on the display. When the
digits for the hours start blinking, you can set the hour at which the
device should switch to the high position. The hours will start count-
ing upwards as soon as the button is pressed. You can set the desired
hour by briefly pressing the button again. The minutes will start blinking
5 seconds after you have released the button, and you can then set
the minutes. The settings will be saved, and the current time will be
displayed after 5 seconds.
‘SEt’: The ‘SEt’ indication will appear if you press the button four times in
the rest position. This means: Set clock. The real time clock is hereby set.
The clock can be set by pressing and holding the button for 3 seconds
when the ‘SEt’ indication is visible on the display. You can set the hours
when the digits for the hours start blinking. The hours will start counting
upwards as soon as the button is pressed. You can set the desired hour
by briefly pressing the button again. The minutes will start blinking 5 sec-
onds after you have released the button, and you can then set the
minutes. The settings will be saved,
and the current time will be displayed after 5
seconds.
‘rSt’: The ‘rSt’ indication will appear if you press
the button five times in the rest position.
This means: Reset. This option is used to reset
the timer.
After you have replaced the lamp and the filter,
you can reset the timer to 8,000 hours.
The timer can be reset to 8,000 hours by pressing and holding the but-
ton for 3 seconds while the ‘rSt’ indication is visible on the display. The
settings will be saved, and the current time will be displayed after 5
seconds.
‘0000.’: The display will indicate 0000 when the 8,000 operating hours of
the lamp have expired. The actual time will blink in the display, alter-
nating with four blinking zeros. The filter and the UV-C lamp must now
be replaced. See item ‘rSt’ for resetting the timer.
‘FAIL’: The software stops if there is a problem with the real time clock
or with the ventilator connection. As soon as the device is switched on,
the program will carry out a self-test to check the proper operation of
the product. The units that are checked are the real time clock and the
ventilator connection. Any problems with these items will be indicated
on the display.
Switching off the display illumination
The display illumination can be switched off by pressing and holding
down the display button for 10 seconds. This will not switch the device
off, and the settings will be retained. The display illumination is switched
on again by briefly pressing the display button once.
Switching off the device
It is not necessary to switch off the device during the day because it
has been designed to operate 24 hours a day to avoid the formation
of new micro-organisms. You can switch the device off by removing
the plug from the socket.
Dismantling / Maintenance
During maintenance work, or when dismantling the device, always
switch off the power supply by removing the plug from the socket. The
device must be cleaned at least once a year.
If dust deposits on the filter more quickly, the filter should be replaced more
than once a year. The special lamp must be replaced after 8,000 operat-
ing hours at the latest. Clean the aluminium interior with a soft cloth.
1. Unscrew the Viroxid
®
Habitat 3 + cover the clips (see Drawing 4)
openand remove the Viroxid
®
Habitat 3 from the clips (A).
2. Using a screwdriver, unscrew the 2 screws (B) from the filtergrid (C) on
the underside of the device.
3. Loosen the filter grid (C) and remove the filter (E) from thefilter holder (D).
4. Carefully pull the UV-C lamp (F) from the lamp fitting (H), thenturn it
by a quarter-turn to enable you to easily remove theUV-C lamp (F)
from the lamp clip (G) of the device.
5. Clean the interior of the aluminium housing (L) with a soft cloth.
6. Carefully insert the (new) UV-C lamp (F) into the lamp clip (G) in
a vertical position, pushing the UV-C lamp (F) through until italmost
reaches the lamp fitting (H). Turn the lamp by a quarter-turn to fix it
more tightly into the lamp clip (G), and thencarefully push the lamp
into the lamp fitting (H) (see Drawing 6).
Summary of Contents for Viroxid HABITAT 3 AIR 160
Page 1: ...HABITAT 3 AIR 160 AIR PURIFIER viroxid...
Page 2: ......
Page 4: ...4 Manual Instructions viroxid HABITAT 3 GB I H K F L D E C B M 1 A...
Page 5: ...5 Manual Instructions viroxid HABITAT 3 GB A A D G F H F 2 4 6 3 5 Center to center 435 mm...
Page 10: ...10 Manuale dell utente viroxid HABITAT 3 IT I H K F L D E C B M 1 A...
Page 11: ...11 Manuale dell utente viroxid HABITAT 3 IT A A D G F H F 2 4 6 3 5 Da centro a centro 435 mm...
Page 16: ...16 Gebrauchsanweisung viroxid HABITAT 3 DE I H K F L D E C B M 1 A...
Page 17: ...17 Gebrauchsanweisung viroxid HABITAT 3 DE A A D G F H F 2 4 6 3 5 Mitte zu mitte 435 mm...
Page 22: ...22 Manuel de l utilisateur viroxid HABITAT 3 FR I H K F L D E C B M 1 A...