All threshold commands:
Action
Code
Command
Ext. Command
Data
Increase the reporting
threshold to 50 SMSes
1234
Report
Threshold
50 073 917 0759
Decrease the reporting
threshold to 14 SMSes
1234
Report
Threshold
14 Sid
2.5.
Arm/Disarm
Master and Arming phone numbers are able to arm or disarm the 805 Alarm Panel. Arming the
panel requires a valid user code for the partition you want to arm/disarm.
To away arm partition 1 you will use the following information:
Code – 1234 (a valid user code in partition 1)
Command – Arm
Extended Command – *
Not needed
Data – P1 (Partition number or name)
The SMS should look like this:
1234 arm p1
To stay arm partition 1 you will use the following information:
Code – 1234 (a valid user code in partition 1)
Command – Arm
Extended Command – S2
Data – Flat (Partition number or name)
The SMS should look like this:
1234 arm s2 flat
All arm/disarm commands:
Action
Code
Command
Ext. Comm
Data
Away arm all partitions
1234
Arm
All
Away arm P1 & P2
1234
Arm
P1,P2
Stay arm ‘house’
1234
Arm
S1
house
Stay arm P1
1234
Arm
S2
P1
Disarm all partitions
1234
Disarm
All
Disarm beams
1234
Disarm
beams
Disarm P1 & P2
1234
Disarm
P1,P2
*Remember the SMS Duo v2 onboard zones are in partition 2 and needs to be armed to be
violated. Except when using the Duo in standalone mode zones 9 & 10 are 24 hour zones and
don’t need to be armed.