background image

 

 

You can also name the cell number when adding it to the SMS Duo V2. 

The SMS should look like this: 

1234 add master 0740492481:Sid 

 

All phone number commands: 

 

Action 

Code 

Command 

Ext. Command 

Data 

Add phone number as a 

Master number 

1234 

Add 

Master 

074 049 2481 

Add phone number as 

an Arm number 

1234 

Add 

Arming 

073 917 0759 

Add phone number as a 

Reporting number 

1234 

Add 

Reporting 

071 348 9467 

Add and name phone 

number as a Master  

1234 

Add 

Master 

074 049 2481:Sid 

Deleting a phone 

number 

1234 

Delete 

 

074 049 2481 

 
 

2.3.

 

Reporting 

 

Each phone number can turn reporting off, as well as choose how they want to receive 

reporting messages. 

On/Off – Enables/Disables reporting to the phone. 

Global – All enabled global events. Eg. System Trouble. 

P1 – Events that are alarm based. Eg. Arm/Disarm. 

P2 – Reports SMS Duo v2 onboard zones 9 & 10. 

 

Type – Enables the type of reporting that the phone number will receive. 

There are three types to choose from: 

Raw – A contact ID string is sent to the phone. 

Full – All enabled events will be sent to the phone in English. 

Reduced - Only the following will be reported: Arm/Disarm, Zone violations, Panics, 

System Troubles. (This is the default) 

Minimal - Only the following will be reported: Zone violations, Panics, System Troubles. 

 

To turn on reporting for partition 1 and global you will use the following information: 

Code – 1234 (a user code) 

Command – Report 

Extended Command – On P1, global 

Data – 074 049 2481 (the number or cell name to receive the reporting SMSes) 

 

The SMS should look like this: 

1234 report on p1,global 0740492481 

 

To change reporting to full you will use the following information: 

Code – 1234 (a user code) 

Command – Report 

Extended Command – Type 

Data – Full Sid 

 

 

Summary of Contents for SMS Duo V2

Page 1: ...ur premises The SMS Duo V2 module works with the IDS 805 Alarm Panel and consists of an X SMS module and an interface that connects it to the 805 panel The SMS Duo V2 can also work as a standalone dev...

Page 2: ...d the 805 Alarm Panel is shown in the image above 1 2 Standalone Connection The SMS Duo V2 in standalone operation only needs a 12V power supply The zone inputs monitor for an open or closed condition...

Page 3: ...y on power up and quickly once the module is running and the power up sequence has completed Network Status LED flashes when connected to the cell provider s network and accepted by the service provid...

Page 4: ...cating with the SMS DUO V2 Off An IDS805 has been detected but is not communicating with the SMS DUO V2 1 6 Interface Board Jumpers The interface board has 3 jumpers to enable disable certain hardware...

Page 5: ...ions in the 805 Alarm Panel 2 2 Adding Phone Numbers In the default state any cell phone can be used to enter the first Master Phone Number you can only add another phone number to the SMS Duo V2 usin...

Page 6: ...Events that are alarm based Eg Arm Disarm P2 Reports SMS Duo v2 onboard zones 9 10 Type Enables the type of reporting that the phone number will receive There are three types to choose from Raw A con...

Page 7: ...rtitions to a phone number 2 4 SMS Threshold By default there is a threshold of 20 SMSes per day to a single phone number You can increase or decrease this threshold by sending a threshold command The...

Page 8: ...number or name The SMS should look like this 1234 arm p1 To stay arm partition 1 you will use the following information Code 1234 a valid user code in partition 1 Command Arm Extended Command S2 Data...

Page 9: ...Panel Status Using the SMS Duo V2 you are able to check the status of various parts of the panel such as Arm Status Zone Status Bypass Status and PGM Status To check the arm status of partition 1 you...

Page 10: ...tus of PGM 2 you will use the following information Code 1234 a valid user code in partition 1 Command PGM Extended Command Status Data 2 PGM number The SMS should look like this 1234 pgm status 4 All...

Page 11: ...mber Name The SMS should look like this 1234 zone name 2 kitchen 3 dining To name a cellphone user you will use the following information Code 1234 a valid user code in partition 1 Command cellnumber...

Page 12: ...have access to this feature To set the missed call command to arm partition 1 you will use the following information Code 1234 a valid user code Command Missedcall Extended Command Set Data 1234 arm p...

Page 13: ...nd By default hints is turned on for each user To enable hints you will use the following information Code 1234 a valid user code Command Hint Extended Command On Data 0713489467 Cell Number The SMS s...

Page 14: ...ta reporting 1234 Report Type Raw 071 348 9467 Increase the reporting threshold to 50 SMSes 1234 Report Threshold 50 074 049 2481 Arm Disarm Away arm all partitions 1234 Arm All Away arm P1 P2 1234 Ar...

Page 15: ...P1 Retrieve the status of zones in partition 1 2 1234 Zone Status P1 P2 Get PGM 2 s status 1234 PGM Status 2 Get PGM Gate s status 1234 PGM Status Gate Retrieve bypass status of zone 1 1234 Bypass Sta...

Page 16: ...e 1234 Help Airtime List ext commands for lockout 1234 Help Lockout List ext commands for PGMs 1234 Help PGM List ext commands for zones 1234 Help Zone List ext commands for reporting 1234 Help Report...