8.1                      Adding, Deleting and Editing User Codes                    

 

Hold [*] + [MASTER USER CODE] + [*] + [PROGRAMMABLE OPTION] + [*] 

 

All IDS Alarm Panels utilise a user-friendly programmable interface which allows the user to add, modify, 

or delete user codes. See Table 3 for a summary of programmable options. The programmable interface 

is accessed by entering the 

USER PROGRAMMING MODE.

 

 

Table 3 : User Programming Options 

 

Options 

Summary of Programmable Options 

816  1224  1632 

Option 0  Allows for the addition of new user codes. 

Option 1  Allows editing of the user name displayed by LCD keypads. 

This menu is only applicable if LCD keypads are installed. 

Option 2  Allows editing of a selected user code. Note that the user 

code properties are not edited, only the user code itself. 

Option 3  Allows viewing of the user code slot number for a selected 

code. 

Option 4  Allows editing of the user code properties for a selected 

user code. This is a bitmapped menu. 

Option 5  Allows the allocation of a selected user code to a 

designated partition(s). This is a bitmapped menu. 

Option 6  Assign User Code to Doors (bitmapped) 

 

 

Option 7  Assign a User Code to a Schedule 

 

 

Option 8  Allows a remote to be assigned to a specific user 

Option 9  Allows a user to be deleted 

Option 10  Allows the deletion of a user code using the user code slot 

number. 

Option 11  Allows viewing of a user name if the slot number is known. 

Option 12  Add User by Slot Number 

 

 

NB:    

Text prompts displayed on LCD Keypads connected to the IDS 1224 and IDS 1632 are considerably 

more detailed than text prompts displayed on the IDS 816 Alarm Panel. 

 

8.2                     How to Enter the User Program Mode                            

 

1.

 

Ensure that the panel is not armed. 

2.

 

Hold down the 

[

*

]

 key until the keypad buzzer sounds. The ARM indicator will flash. 

3.

 

The LCD prompt reads 'Enter Master Code'. The factory default is 

[1234].

 Should the 

[MASTER 

USER CODE]

 be set to six digits it will be 

[123456]

 by default. 

4.

 

After entering the 

[MASTER USER CODE],

 press the

 

[

*

]

 key. A valid entry will be confirmed by 

a long beep. If an invalid 

[MASTER USER CODE]

 was entered, the keypad buzzer will give an 

error beep (3 short beeps). 

If steps 1 - 4 are performed correctly: 

5.

 

IDS 816 Panel

 

The LCD display will prompt for a 'Menu Option'.  

Summary of Contents for LCD Digital Keypad

Page 1: ......

Page 2: ...2 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Page 3: ...3 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Page 4: ...4 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Page 5: ...Fire Alarms 12 5 2 Panic Alarms 12 5 3 Medical Alarms 13 5 4 Duress Alarms 13 6 Alarm Memory 13 7 Zone Options 13 7 1 Changing a Zone Name 13 8 User Codes 14 8 1 Adding Deleting and Editing User Code...

Page 6: ...0 Delete a User Code Slot Known 23 8 3 12 Option 11 Viewing a User Code 23 8 3 13 Option 12 Add User Slot 24 9 Stay Zones 24 9 1 How to Select a Stay Profile 24 9 2 How to Program Stay Zones 24 9 3 Ho...

Page 7: ...0 292 01C Issued March 2009 Tables Table 1 Alarm Panel Zones 13 Table 2 Alarm Panel Features 14 Table 3 User Programming Options 15 Table 4 User Code Properties 19 Table 5 Trouble Conditions 27 Table...

Page 8: ...ed by motion detectors If necessary bypass any required zones and close the front door 2 Press the key 3 Enter a valid USER CODE If an incorrect code is entered the keypad buzzer will beep three times...

Page 9: ...ing television when all interior zones would be bypassed See 9 1 How to Select a Stay Profile 2 2 1 How to Stay Arm USER CODE Do not leave premises 1 Select the required STAY PROFILE See Section 8 1 2...

Page 10: ...e the PANIC and MED keys to scroll through zones which have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a designated exit route 2 At the en...

Page 11: ...e system will disarm and the remote indicator if installed will turn off If the siren toot on disarm option is enabled the siren will provide a double toot when the panel is disarmed 4 Bypassing Zones...

Page 12: ...on will be activated The Display reads Alarm alongside the relevant partition The FIRE ALARM CONDITION may also be triggered by a smoke detector connected to an appropriately programmed zone The siren...

Page 13: ...can be easily remembered by all family or staff members 6 Alarm Memory The Alarm Memory displays any zones which were tampered violated or bypassed during the last arm cycle A flashing ARM indicator...

Page 14: ...i e to display a 2 press the relevant key four times If you wish to use a different letter on the same key press the key the required number of times to display the relevant letter pause for one secon...

Page 15: ...d user code to a designated partition s This is a bitmapped menu x x x Option 6 Assign User Code to Doors bitmapped x Option 7 Assign a User Code to a Schedule x Option 8 Allows a remote to be assigne...

Page 16: ...r Code Hold Master Code 0 New Code 1 Enter the User Program Mode as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 0 key followed by the key to select programmable op...

Page 17: ...Example You wish to change USER 1 to read Brad 1 To type in a B press the 2 key twice B is the second letter displayed on the key 2 Text is defaulted to Upper case Press the MODE key for lower case Up...

Page 18: ...Code Property Number 1 Enter the User Program Mode as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 4 key followed by the key to select programmable option 4 IDS 16...

Page 19: ...ol panel disarms normally however a DURESS REPORTING CODE is transmitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder It is advisable t...

Page 20: ...l disarm all of the assigned partitions In a case where some partitions are disarmed and others armed entering this group code at the keypad of the armed partition will disarm the armed partitions onl...

Page 21: ...will be a Y next to Option 1 and the user can thus arm and disarm partition 1 If the user is assigned to partition 4 there will be a Y next to Option 4 It is possible to program codes to arm disarm an...

Page 22: ...If a user is assigned to Schedule 0 the user may arm disarm the premises at any given time Users assigned to Schedule 1 are allowed to arm disarm the area only during the specified programmed schedule...

Page 23: ...de as per steps 1 4 of 8 2 2 IDS 816 Panel When prompted for the Menu Option press the 1 key followed by the 0 key to select programmable option 10 IDS 1632 IDS 1224 Panels Menu option 0 Add User is d...

Page 24: ...hose zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms which are protected by Passive Infra Red PIR detectors or windows which m...

Page 25: ...ively use the PANIC and MED keys to scroll through zones 4 A N next to the zone number indicates that the zone is not selected as a stay zone 5 Repeat step 3 until all the required stay zones have bee...

Page 26: ...4 A N next to the zone number indicates that the zone has not been selected as a buzz zone 5 Repeat step 3 until all the required buzz zones have been cancelled 6 Press the key to exit the buzz zone...

Page 27: ...is also possible to enable a trouble beep If the trouble beep has been enabled the keypad buzzer will sound to alert the user that a trouble condition has occurred Press the key to silence the buzzer...

Page 28: ...e ring Dial in again within 1 minute the panel will pick up immediately and transmit handshake tones consisting of a high pitch tone for two seconds followed by a lower pitch tone for one second Withi...

Page 29: ...tes that the zone was successfully un bypassed Three Error Beeps indicates that a key entry error has occurred Check Zone Bypass Status 2 3 ZONE A Single Beep indicates that the zone is bypassed A Dou...

Page 30: ...to control switching functions via its outputs these can be controlled via the keypad e g turning lights on and off Hold down the MODE key and press 3 Any outputs that are currently set ON will be dis...

Page 31: ...er Code Press Tx Button Delete a User Code by Code Master Code 9 User Code Delete a User Code by Slot Number Master Code 10 Slot Number Change Partitions Mode 1 Partition Number Select a Stay Profile...

Page 32: ...32 IDS LCD Keypad User Manual 700 292 01C Issued March 2009...

Reviews: