44
Rotate
THIS FEATURE IS NOT SUPPORTED IN SMART-21.
Etc
“Cleaning Roller” is to clean the roller by cleaning card automatically. “Use Log” is to
display log in message space.
(3) Print
Print can be done through the CSD file which is designed by SMART IDesigner program.
Following the steps in this section.
1.
Click
“…”
button and select the CSD file.
2.
Click
“Open”
button to prepare CSD file to print.
3.
Click
“Print”
Button
to move print data to spool. In the NORMAL mode, Click “Print” button
to print a card, but in the SBS mode, “Print” button to transmit a printing data from PC to
printer and wait for printing. Therefore, you must click “DoPrint” to print in SBS mode. This
function is for detail control of printer.
4.
Click
“Close”
button to close CSD file.
(4) Batch
Batch
is to repeat encoding/decoding test continuously. In the Repeat, you input the number of
repeat and click “Batch Start”, then the test is run as many times as the number of set. When you
check
“Include Card In/Out”
, each time the printer bring a card from card slot and perform an
encoding test and eject the card. So, cards should be entered manually as many times as the
number of set. But if not, encoding test will be done only by one card. At that time, if there is no
card in the printer, the printer bring a card from card slot and repeat the encoding test on the card,
and if there is a card in the printer, the encoding test is performed on the card repeatedly.
“Card
Holding”
is activated when “Include Card In/Out” is ticked. When “Card Holding” is ticked and the
repeat number is set, the printer repeats the encoding test as many times as the number of set in
the “Card Holding” without ejection. When it is completed, the printer ejects the card and brings a
new card into the printer from card slot and starts testing.
In the Setting,
“Retry”
is to retry the encoding test when the error occurred.
“Prompt on Error
” is
to display Pop up Message when the error occurred. If not, Error number will be counted without
message. The number of error is displayed at Error section
.