(C) IDM Energiesysteme GmbH
Installation instructions AERO ILM
67
40
35
30
25
20
15
cooling capacity [kW]
12,61
13,94
15,12
16,14
-
-
power consumption [kW]
4,55
4,07
3,71
3,45
-
-
EER
2,77
3,43
4,07
4,69
-
-
cooling capacity [kW]
8,78
9,48
10,02
10,38
-
-
power consumption [kW]
2,64
2,31
2,12
1,99
-
-
EER
3,33
4,10
4,73
5,21
-
-
cooling capacity [kW]
6,56
6,94
7,16
7,22
-
-
power consumption [kW]
2,39
2,10
1,90
1,74
-
-
EER
2,74
3,30
3,77
4,15
-
-
40
35
30
25
20
15
cooling capacity [kW]
10,94
12,27
13,45
14,48
15,34
-
power consumption [kW]
4,87
4,36
3,97
3,63
3,46
-
EER
2,25
2,82
3,38
3,99
4,43
-
cooling capacity [kW]
7,04
7,74
8,28
8,65
8,85
-
power consumption [kW]
2,57
2,20
2,00
1,86
1,78
-
EER
2,74
3,51
4,14
4,64
4,98
-
cooling capacity [kW]
4,91
5,29
5,52
5,58
5,49
-
power consumption [kW]
2,14
1,85
1,65
1,52
1,40
-
EER
2,29
2,86
3,35
3,68
3,93
-
40
35
30
25
20
15
cooling capacity [kW]
8,59
9,79
10,85
11,77
12,55
13,18
power consumption [kW]
4,15
3,71
3,39
3,02
2,86
2,80
EER
2,07
2,64
3,20
3,89
4,39
4,70
cooling capacity [kW]
6,01
6,76
7,34
7,74
7,95
8,00
power consumption [kW]
2,66
2,23
2,01
1,86
1,77
1,70
EER
2,25
3,03
3,65
4,15
4,49
4,69
cooling capacity [kW]
4,12
4,56
4,83
4,90
4,79
4,50
power consumption [kW]
1,74
1,49
1,33
1,20
1,09
0,98
EER
2,36
3,06
3,64
4,09
4,41
4,57
MIN
outdoor temperature [°C]
W18
MAX
NOMINA
L
outdoor temperature [°C]
W12
MAX
NOMINA
L
MIN
outdoor temperature [°C]
W7
MAX
NOMINA
L
MIN
Appendix
App
end
ix
9.4. AERO ILM 4-13 - Performance data cooling - detailed
To guarantee a correct cooling mode, when working with unregulated direct-heating circles (without cooling
EXႇHUIROORZLQJSRLQWVKDYHWREHPHW
1) To ensure the minimum volume of heating site, appropriate zones have to remain open all the time.
Minimum volume 144 lt.
7R HQVXUH WKH PLQLPXP ÀRZ UDWH RI KHDWLQJ VLWH DSSURSULDWH ]RQHV KDYH WR UHPDLQ RSHQ DOO WKH WLPH
0LQLPXPÀRZUDWHPñK
3) To ensure the minimum cooling output rate of distribution system, appropriate zones have to remain open
DOOWKHWLPH7KHPLQLPXPFRROLQJRXWSXWUDWHLVRIWKHPLQLPXPFRROLQJRXWSXWSRZHURIWKHKHDWSXPSDW
A35/W18. Minimum cooling consumption 5.1 kW
$OO SRLQWV PXVW EH IXO¿OOHG LQGHSHQGHQWO\ 7KLV LV SRVVLEOH YLD WKH 1DYLJDWRU 3UR 7KH HQWLUH GLVWULEXWLRQ
V\VWHPKDVWRIXO¿OOWKHPHQWLRQHGSRLQWV
To ensure a large cooling demand, the cooling limit has to be set as high as possible.