(C) IDM ENERGIESYSTEME GMBH
Installation instructions AERO ILM
5
General description
For the installation of the heat pump all
pertinent national and international lay-
ing, installation, accident prevention and
safety regulations in connection with the
installation of pipeline systems and elec-
tric components and equipment as well as
instructions in this assembly manual must
be observed.
1.8. Ice-covering weather-shield grilles
Depending on the weather and outdoor humidity, it
may happen that there will be formed an icy coverng
on the wheather-shield grilles of the heat pump. This
HႇHFW LV FRPPRQ RFFXULQJ LQ QDWXUH 7KLV FRYHULQJ
must be removed by the heat pump operator during
this weather periods.
1.9. Installation area
1.10. Information on environmental protection
- In order to minimize oscillations and sounds
within buildings, heat pumps should be decou-
pled as far as possible from the building mass.
It is principally recommended to avoid installing
KHDWSXPSVRQFHLOLQJVDQGÀRRUVLQOLJKWZHLJKW
FRQVWUXFWLRQ,QWKHFDVHRIÀRDWLQJÀRRUVFUHHG
ÀRRUVFUHHGDQGLPSDFWVRXQGLQVXODWLRQVKRXOG
be omitted around the heat pump.
- The installation in wet or damp environments or
in areas exposed to dust or explosion hazards is
non-permissible.
- If refrigerant escapes from the installation site,
this must not enter adjacent rooms, stairways,
yards, corridors or drainage systems and a
hazard-free drainage must be ensured.
- In the case of danger, leave the installation site
immediately.If the size of the installation site falls
below the requested minimum size, this has to
be designed as machinery room in compliance
with EN 378.
-
,I WKH HPHUJHQF\ YHQWLODWLRQ LV QRW VXႈFLHQW
mechanical ventilation must be provided. A
mechanical ventilation shall be installed with
an independent emergency control beyond the
installation site and near the door to that area.
- Heat pumps must not be installed in rooms with
KLJK(0&ORDG$LULQWDNHVDQGRXWOHWVKDYHWREH
safeguarded against theft by appropriate on-site
measures.
- The AERO ILM heat pump has to be
installed in a frost-proof room! (room
WHPSHUDWXUHPXVWOLHEHWZHHQ&DQG
&
Heat pumps are electronic devices of
high-quality material which must not be
disposed of in the same way as house-
hold waste. They must be disposed of in
a professional and appropriate manner
pursuant to the regulations of the local
authorities. Disposal contrary to the
regulations may lead damage the envi-
ronment and health with the exception
of sanctions imposed on law breakers.
1.11. Piping and pipe-wall-ducts
All pipelines and wall ducts must be discharged in
compliance with standards, according heat-insula-
tion, sound-decoupling and water-carrying pipes in a
frost-proof manner.
1.12. Installation of additional components
The installation of additional components which have
QRWEHHQYHUL¿HGZLWKWKHHTXLSPHQWPD\LPSDLUWKH
function. No warranty or liability shall be assumed for
any damage resulting therefrom.
1.13. Standards and guidelines
These comprise among others:
- the generally valid accident prevention and safety
regulations
- the provisions regarding environmental protection
- the regulations of the professional associations
- the pertinent laws, standards, regulations and pro-
visions, e.g. DIN, EN, DVGW, VDI and VDE.
- Provisions of the local public utilities.