background image

NJR-TW01UHD/NJR-RW01UHD Command Guide 

44 

 

 

 

 

User Guide (Command Guide) of NJR-TW01UHD/NJR-RW01UHD 

Ver.1.0.0 

Issued on: 17 July 2019 

 

 

 

 

 

 

 

 

 

Information in this document is subject to change without notice. 
©2019  IDK Corporation, all rights reserved. All trademarks mentioned are the property of their 
respective owners. 

 

 

Headquarters 

IDK Corporation 

7-9-1 Chuo, Yamato-shi, Kanagawa-pref. 

242-0021 JAPAN 

TEL: +81-46-200-0764 FAX: +81-46-200-0765 

Email: [email protected] URL: 

http://www.idkav.com

 

 

USA 

 

 

 

IDK America Inc. 

72 Grays Bridge Road Suite 1-C, Brookfield, CT 06804 

TEL: +1-203-204-2445 

Email: [email protected] URL: 

http://www.idkav.com

 

 

Europe 

 

 

IDK Europe GmbH 

Lise-Meitner-Str. 6, D-40878 Ratingen 

TEL: +49-2102-578-301-0 

Email: [email protected]   URL: 

http://www.idkav.com

 

 

 

Product information 

Support 

Arvanics Corporation 

7-9-1 Chuo, Yamato-shi, Kanagawa-pref. 

242-0021 JAPAN 

TEL: +81-46-259-6920 FAX: +81-46-259-6930 

Email: [email protected] URL: 

http://www.arvanics.com

 

Summary of Contents for NJR-RW01UHD

Page 1: ...HD Command Reference Guide Ver 1 0 0 Thank you for choosing our product To ensure the best performance of this product please read this user guide fully and carefully before using it and keep this man...

Page 2: ...trademarks of HDMI Licensing Administrator Inc in the United States and other countries Connection Reset and IP NINJAR are registered trademarks of IDK Corporation in Japan All other company and prod...

Page 3: ...guide is subject to change without notice You can download the latest version from IDK s website at http www idkav com The reference manual consists of the following two volumes User guide Please down...

Page 4: ...3 2 2 LAN communication specification 11 3 3 Controlled by IP NINJAR Configurator 11 3 3 1 Setting LAN communication 11 3 4 External control from NJR CTB 13 4 Command 14 4 1 Summary 14 4 2 Command li...

Page 5: ...support command control of RS 232C communication The RS 232C communication is for command transmission pass through Perform command control of NJR TW01UHD RS 232C model from NJR RW01UHD or IP NINJAR d...

Page 6: ...uide NJR TW01UHD NJR RW01UHD NJR TW01UHD NJR RW01UHD User Guide NJR TW01UHD NJR RW01UHD Command Guide NJR T01SDI NJR T01SDI User Guide NJR T01SDI Command Guide NJR T04HD NJR R04HD NJR T04HD NJR R04HD...

Page 7: ...NJR TW01UHD NJR RW01UHD Command Guide 7 2 About this Guide Communication commands enable the following main operations Setting input output Setting audio Setting EDID Displaying information...

Page 8: ...C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal name RD TD N C N C N C N C GND RTS CTS Signal name Receive Data Transmit Data Ground Request to Send Clear to Send NJR W01UHD Cross cable Cont...

Page 9: ...to form a loop by the NJR TW01UHD LAN model NJR RW01UHD when connecting a LAN cable to the NJR TW01UHD LAN model NJR RW01UHD The NJR TW01UHD LAN model NJR RW01UHD constantly send broadcast packet in...

Page 10: ...Received data RX Received data 2 TRX Transmitted Received data TX Transmitted data TRX Transmitted Received data RX Received data 3 TRX Transmitted Received data RX Received data TRX Transmitted Recei...

Page 11: ...from NJR RW01UHD or IP NINJAR device connected to 10 GbE switch For operations from the IP NINJAR Configurator refer to the User Guide of IP NINJAR Configurator The IP NINJAR Configurator can be down...

Page 12: ...UHD LAN model and NJR RW01UHD by connecting to either NJR TW01UHD or NJR RW01UHD LAN connector Audio A 2 Audio D 1 Video Audio D 1 D A conversion Audio A 2 or D 1 Fiber optic cables NJR TW01UHD LAN mo...

Page 13: ...refer to the Command Guide of NJR CTB MAINTENANC connector Tablet MAINTENANCE NJR CTB PC for control LAN cable 2 Communication command TCP 1100 Command server WEB server Browser HTTP 80 LAN LAN connec...

Page 14: ...etween two parameters is indicated as a delimiter CR LF return line feed 0D and 0A in hex If an error occurs An error response is returned if an undefined command or inappropriate parameter is include...

Page 15: ...uration 25 Setting Audio Command Function Page GAM SAM Muting unmuting digital audio output 26 GAAS SAAS Output audio 27 Setting EDID Command Function Page GVF SVF EDID resolution 28 RME Copying EDID...

Page 16: ...NJR TW01UHD NJR RW01UHD Command Guide 16 Information Command Function Page GSS I O status 38 GES Monitor EDID 41 GIV Version 43...

Page 17: ...NJAR Configurator LAN Setting input GDT SDT Command WEB C GHE SHE Command WEB C Setting output GDM SDM Command WEB C GEN SEN Command WEB C GHM SHM Command WEB C Setting Audio GAM SAM Command WEB C GAA...

Page 18: ...ut from the NJR CTB any channel can be specified because multiple NJR W01UHD devices that are connected over a network switch can be controlled Example Format SAM device ch port mute Parameter device...

Page 19: ...E switch LAN cable Fiber optic cables SAM 1 64 1 1 PC for control NJR TW01UHD NJR RW01UHD Input channel 1 LAN cable NJR TW01UHD NJR RW01UHD Input channel 64 Output channel 1 Output channel 64 SAM 2 1...

Page 20: ...se in case the command is not executed Response ERR error Parameter error Error status 1 Erroneous parameter format or value 2 Undefined command or wrong format 3 Currently cannot be used 99 Error oth...

Page 21: ...nector 1 fixed time No signal input monitoring 0 OFF 2000 to 15000 2 sec to 15 sec Default 10000 10 sec Set the value by 1000 ms If you set a value other than 0 for the lower 3 digits these values wil...

Page 22: ...nel 1 to Input channel 512 If a command is input from the IP NINJAR Configurator 1 is set fixed port Input connector 1 fixed hdcp HDCP input enabled disabled 0 DISABLE 1 ENABLE Default Getting example...

Page 23: ...t connector mode_1 to mode_2 mode Output mode 0 AUTO Default 1 DVI output 2 RGB output 3 YCbCr4 2 2 output 4 YCbCr4 4 4 output 5 YCbCr4 2 0 output NJR TW01UHD mode_1 Output connector for extension mod...

Page 24: ...s input from the IP NINJAR Configurator 1 is set fixed reserved Reservation 1 fixed port Output connector 1 fixed hdcp HDCP output 1 ALWAYS Default 2 HDCP INPUT ONLY 3 HDCP 2 2 Getting example Command...

Page 25: ...ing request signals Default 2000 to 15000 2 sec to 15 sec Set the value by 1000 ms If you set a value other than 0 for the lower 3 digits these values will be rounded down For example if you set it to...

Page 26: ...NJR TW01UHD 2 NJR RW01UHD ch Channel 1 to 512 Channel 1 to Channel 512 If a command is input from the IP NINJAR Configurator 1 is set fixed port Connector 1 fixed mute Audio mute 0 Mute OFF Default 1...

Page 27: ...g input audio Default 1 Digital input audio digital Digital audio output connector 0 Analog input audio 1 Digital input audio Default Getting example Command Response GAAS 2 1 1 GAAS 2 1 1 0 1 Descrip...

Page 28: ...1280x720 13 WXGA 1280x768 14 WXGA 1280x800 15 Quad VGA 1280x960 16 SXGA 1280x1024 17 WXGA 1360x768 1366x768 18 SXGA 1400x1050 19 WXGA 1440x900 20 WXGA 1600x900 21 UXGA 1600x1200 22 WSXGA 1680x1050 23...

Page 29: ...ed Remarks The NJR RW01UHD does not support this command GWX SWX Selecting WXGA mode Getting Command GWX device ch port Response GWX device ch port mode Setting Command SWX device ch port mode Respons...

Page 30: ...put channel 512 If a command is input from the IP NINJAR Configurator 1 is set fixed port Input connector 1 fixed color Color depth 0 24 BIT COLOR Default 1 30 BIT COLOR 2 36 BIT COLOR Getting example...

Page 31: ...192 kHz Default PCM 48 kHz others OFF OFF Only setting command SAF can be used The selectable maximum sampling frequency depends on audio format Audio format Maximum sampling frequency kHz PCM 32 44...

Page 32: ...7 Front Left Right Wide 8 Front Left Right High 9 Top Center 10 Front Center High Getting commands the number of speakers and which speakers will be used is returned Setting commands if you do not sp...

Page 33: ...le Command Response SSP 1 1 1 8 SSP 1 1 1 8 Description Assign eight speakers to Channel 1 Front Left Right Low Frequency Effect Front Center Rear Left Right Rear Left Right Center Completed Setting e...

Page 34: ...5200 bps databit Data bit length 7 7 bit 8 8 bit Default stopbit Stop bit 1 1 bit Default 2 2 bit parity Parity check 0 NONE Default 1 ODD 2 EVEN Getting example Command Response GCTB 1 1 1 GCTB 1 1 1...

Page 35: ...eway Default gateway 0 to 255 8 bit in decimal x 4 combinations Default Getting automatically Getting example Command Response GIP 1 1 1 GIP 1 1 1 1 192 168 3 2 255 255 255 0 192 168 3 254 Description...

Page 36: ...model 2 NJR RW01UHD ch Channel 1 to 512 Channel 1 to Channel 512 reserved Reservation 1 fixed mac MAC address 00 to FF 8 bit in hex x 6 combinations Getting example Command Response GMC 1 1 1 GMC 1 1...

Page 37: ...s of the NJR TW01UHD Channel 2 Completed Remarks This command can be input only via the NJR CTB command server Settings of 4 5 2 1 Setting input to 4 5 2 6 Setting LAN will be initialized RBTC Reboot...

Page 38: ...format 3 4 with without HDCP input 4 For HDMI output connector of NJR TW01UHD NJR RW01UHD 10 All of 11 to 13 11 HDCP authentication status 5 12 Output signal type 6 13 Error code 7 status_1 to status_...

Page 39: ...put HDCP OFF Signal without HDCP is input NO SIGNAL No signal is input 5 For HDCP authentication one of the following values is returned Reply example Description HDCP 1 4 SUPPORT Authenticated with H...

Page 40: ...s for outputting video or audio 7 Signal that is not supported by NJR W01UHD is input Since compressed audio is input audio cannot be output 9 The sink device that does not support audio is connected...

Page 41: ...or depth 3 4 Audio support status sampling frequency bit length the number of channels and compressed audio support status 4 status_1 to status_4 Status 1 For monitor name Reply example Description MS...

Page 42: ...ice supporting audio signal is connected Supported sampling frequency 32 44 1 48 88 2 96 176 4 192 the number of bits 16 20 24 the number of channels 1 to 8 and compressed audio support status are ret...

Page 43: ...UHD ch Channel 1 to 512 Channel 1 to Channel 512 If a command is input from the IP NINJAR Configurator 1 is set fixed reserved Reservation 1 fixed id Model number ver Firmware version Getting example...

Page 44: ...gawa pref 242 0021 JAPAN TEL 81 46 200 0764 FAX 81 46 200 0765 Email idk_eng idk co jp URL http www idkav com USA IDK America Inc 72 Grays Bridge Road Suite 1 C Brookfield CT 06804 TEL 1 203 204 2445...