9.13.7 Command execution key: Illuminating condition
Menu Top
→
PRESET COMMAND
→
COMMAND TALLY
Setting for Each control command execution key
Setting value REGISTERED : Lights if a control command is registered [Default]
*1
EXECUTION : Lights while a control command is executed
*1 *2
If you set “LINK” to “ON”, you can change all lighting conditions at once.
*1
There are two planes (PLANE A and B) for each execution condition of COMMANDs 1 to 32. If you register
control commands for both planes, the control commands are executed alternatively every time you press
the command key as follows.
[Table 9.29] Illuminating condition
Illuminating
condition
If you register a command only for one
plane
If you register commands for both two
planes
REGISTERED
Illuminates if a control command is
registered
Illuminates if PLANE A will be executed at
the next press; blinks if PLANE B will be
executed at the next press.
EXECUTION
Illuminates while a control command is
executed
Illuminates if PLANE A will be executed at
the next press; turned off if PLANE B will
be executed at the next press.
*2
If execution duration is 500 ms or shorter, it illuminates for 500 ms. It can be set blinking in “
Command execution key: Illuminating condition
”.
9.13.8 Blinking at command execution key
Menu Top
→
PRESET COMMAND
→
FLASH TIME
Setting for Each control command execution key, each display power key
Setting value EXECUTION : Blinks while a control command is being executed [Default]
OFF : Not blink
1sec. to 1000sec. : Blinks for the specified time (1 to 1000 sec.)
You can set the blinking duration of command execution keys and power switch of sink devices during
command execution.