FDX-08 Command Guide
73
@GOS
Sink device status (For each channel)
Function
Getting
Format
@GOS,out,mode
Return value
@GOS,out,mode,status_1 (,status_2)
Parameter
out : Output channel
1 to 8 = OUTPUT1 to OUTPUT8
mode: Status
0 = All statuses of sink device, 1 = HDCP of sink device,
2 = HDCP authentication between the FDX and sink device
status_1: HDCP of sink device
Example
Description
HDCP SUPPORT
HDCP compliant sink device is connected.
HDCP NOT SUPPORT
Non-HDCP compliant sink device is
connected.
HDCP NOT CHECK
HDCP of sink device is not checked.
UNCONNECTED
Sink device is not connected.
status_2: HDCP authentication between the FDX and sink device
Example
Description
HDCP OFF
Signal with HDCP is not input.
HDCP OK
Authentication succeeded
HDCP ERROR
Authentication failed
HDCP CHECK NOW
Being authentication processing
Example
@GOS,1,0
@GOS,1,0,HDCP SUPPORT,HDCP OK
Getting all statuses of output channel 1
sink device
The connected sink device is HDCP
compliant and HDCP is authorized
correctly.
Remarks
-