FDX-08 Command Guide
44
@GOT / @SOT
Output resolution (cont’d)
Example
@GOT,1
@GOT,1,1,25
Getting the output resolution setting of
output channel 1
[email protected] (1920x1080) (AUTO)
@SOT,1,0,25
@SOT,1,0,25
Setting the output resolution of output
channel 1 to [email protected] (1920x1080)
Completed
Remarks
Supported since firmware ver.2.xx
@GUM / @SUM Aspect ratio of sink device
Function
Getting
Setting
Format
@GUM,out_ch
@SUM,out_ch,aspect
Return value
@GUM,out_ch,aspect
@SUM,out_ch,aspect
@GUM,out_ch,error
Parameter
out_ch: Output channel
1 to 8 = OUTPUT1 to OUTPUT8
aspect: Aspect ratio of sink device
0 = To be output with aspect ratio of output resolution [Default]
1 = 4:3
2 = 5:3
3 = 5:4
4 = 16:9
5 = 16:10
error:
- 2 = Scan converter output board is not mounted.
Example
@GUM,1
@GUM,1,0
Getting the sink device aspect ratio of
output channel 1
“0” (To be output with aspect ratio of
output resolution)
@SUM,1,0
@SUM,1,0
Setting the sink device aspect ratio of
output channel 1 to “0” (To be output with
aspect ratio of output resolution)
Completed
Remarks
Supported since firmware ver.2.xx