4.3.6 Output timing settings
@GOT / @SOT
Output resolution
Function
Getting
Setting
Format
@GOT,out_ch
@SOT,out_ch,auto,resolution
Return value
@GOT,out_ch,auto,resolution
@SOT,out_ch,auto,resolution
@GOT,out_ch,error
Parameter
out_ch: Output channel
1 to 8 = OUTPUT1 to OUTPUT8
auto: Output resolution mode
0 = Resolution can be specified for the “resolution” parameter below.
1 = Resolution can be selected automatically [Default]
resolution: Output resolution
01 = VGA@60 (640x480)
02 = SVGA@60 (800x600)
03 = XGA@60 (1024x768)
04 = WXGA@60 (1280x768)
05 = WXGA@60 (1280x800)
06 = Quad-VGA@60 (1280x960)
07 = SXGA@60 (1280x1024)
08 = WXGA@60 (1360x768)
09 = WXGA@60 (1366x768)
10 = SXGA+@60 (1400x1050)
11 = WXGA+@60 (1440x900)
12 = WXGA++@60 (1600x900)
13 = UXGA@60 (1600x1200)
14 = WSXGA+@60 (1680x1050)
15 = VESAHD@60 (1920x1080)
16 = WUXGA@60 (1920x1200)
17 = QWXGA@60 (2048x1152)
18 = [email protected] (720x480)
19 = 576p@50 (720x576)
20 = 720p@50 (1280x720)
21 = [email protected] (1280x720)
22 = 1080i@50 (1920x1080)
23 = [email protected] (1920x1080)
24 = 1080p@50 (1920x1080)
25 = [email protected] (1920x1080) [Default]
error:
-2 = Scan converter output board is not mounted.