Part 2 - Configuration
65
Disk Partially
Full
Generates an event when the
disk of one of two groups reaches
their maximum capacity. For more
information on the disk group,
refer to
Disk Full
Generates an event when all disks
reach their maximum capacity.
Disk Bad
Generates an event when the
specified percentage of the
disk becomes damaged. Set to
between 10% and 90% in 10%
intervals.
Disk
Temperature
Specify the threshold temperature.
Once any disk reaches this
threshold, the system will issue an
alert.
Disk
S.M.A.R.T.
Monitors disks that support
S.M.A.R.T. and notifies the user if a
disk error is detected.
Fan Error
Notifies the user when the fan
inside the system (CPU fan, HDD
fan 1, HDD fan 2) malfunctions.
eSATA
Disconnected
Notifies the user if an eSATA device
becomes disconnected while in use.
Disk Config
Change
It will be highlighted when the NVR
reboots after the hard disk drive has
been replaced.
No Storage
Found
It will be highlighted when no hard
disk drive has been connected.
Consecutive
Invalid PW
It will be highlighted when login
fails by entering a wrong password
for consecutive attempts.
Redundant
Power Error
It will be highlighted when the
redundant power is disconnected.
(This feature is supported only with
DR-8364D/DR-8364FD model)
RAID BROKEN
It will be highlighted when the RAID
configuration is broken.
Degrade
It will be highlighted when one of
the HDDs composing RAID is in
error.
•
For system events, only an e-mail notification of
actions can be selected.
•
In order to use the Notify(Callback) feature, the
NVR must be registered to the remote program on
the receiving PC's end.
•
For more information on the RAID Broken and
Degrade,
refer to
.
Camera System
A list of events that occur in the camera except for video
analysis.