IDEXX EquiView
®
Digital Radiography System Operator’s Guide
29
Appendix B—Technique Chart
These settings were applied using a MinXray 80/15 Ultralight on a 1,100-pound quarter horse.
View
kVp
sec
mAs
Film/Focus
Distance
P3
Lateral
66
0.1
1.5
20"
PD
66
0.12
1.8
20"
Navicular
Lateral
66
0.12
1.8
20"
60°
70
0.
4.5
12"–16"
Fetlock
Lat/Obl
66
0.1
1.5
20"–24"
DP
66
0.12
1.8
20"–24"
Carpus
All views
66
0.1
1.5
20"–24"
Skyline
68
0.14
2.1
12"–16"
Tarsus
Lat/Obl
70
0.1
1.5
20"–24"
DP
70
0.12
1.8
20"–24"
Stifle
Lat/Obl
70
0.2
20"–24"
CC
70
0.4
6
close as possible
Neck
C1–
70
0.2
20"–24"
C4ff
70
0.
4.5
20"–24"
Whithers
70
0.
4.5
18"–24"
NOTE:
Higher kVp settings do not always produce a better image. If you are not satisfied with the
penetration or the contrast, try increasing the time (sec), and thereby the dose (mAs).
NOTE:
Generally, the image is improved when the film/focus distance is smaller.